39
Reference Manual
00809-0100-4840, Rev CB
February 2015
9.
Press the red button
to save if the new b.rEF value is correct, or press the blue button
to not save. Afterwards, depending on the button pressed, either the “b.rEF” menu
or the next menu appears.
Note
If the saved duty is Flow or Contents, the next menu option offered is “ProF”
(see the section
“Selecting a profile (on the 3102/3105)” on page 39
).
If the saved duty is Level or Distance, the next menu option offered is “4”
(see the section
“Setting the 4 mA point (on the 3102/3105)” on page 48
4.4.5
Selecting a profile (on the 3102/3105)
Screen display:
ProF
Factory default value: Lin
This menu is offered if the selected duty is Contents (Volume) or Flow, or is shown when
manually navigating the menu system -
this section can be ignored if the selected duty is Level or
Distance
.
The transmitter is pre-programmed with popular profiles that are mathematical formulae to
convert (scale) a linear level reading to a flow or volumetric PV. Once converted (scaled), the
4–20 mA Output and the integral display will operate according to the flow or volumetric PV.
The profile options are described in the following sub-sections:
“Contents (volume) measurement” on page 40
Summary of Contents for Rosemount 3101
Page 2: ......
Page 4: ...ii Reference Manual 00809 0100 4840 Rev CB Title Page February 2015 ...
Page 12: ...x Reference Manual 00809 0100 4840 Rev CB Contents February 2015 Contents ...
Page 34: ...22 Reference Manual 00809 0100 4840 Rev CB Section 3 Installation February 2015 Installation ...
Page 68: ...56 Reference Manual 00809 0100 4840 Rev CB Section 4 Starting up February 2015 Starting up ...
Page 236: ...224 Reference Manual 00809 0100 4840 Rev CB Index February 2015 Index ...
Page 237: ......
Page 238: ......
Page 239: ......