User Manual
Section 5
GFK-2958L
May 2021
Detailed Description of I/O Modules
328
5.28.3
Modifiable Parameters for EP-3368
Channel Description
Options
Default
Frequency suppression
disabled (0) /
50 Hz (1) /
60 Hz (2) /
Average over 16 values (3)
disabled
0 - 7
Measurement range
0 to 20 mA (0) /
4 to 20 mA (1) /
disabled (3)
disabled
5.28.4
Diagnostic Data EP-3368
Name
Bytes
Bit
Description
Default
Error indicator
0
0
Module error
1
Internal error
2
External error
3
Channel error
0
4
Error
5
Reserved
0
6
Reserved
0
7
Parameter error
Module type
1
0
Module Type
0x05
1
2
3
4
Reserved
0
5
Reserved
0
6
Reserved
0
7
Reserved
0
Error byte 2
2
0-7
Reserved
0
Error byte 3
3
0-2
Reserved
0
3
Internal diagnostic FIFO full
0
4
Power supply fault
0
5
Reserved
0
6
Reserved
0
7
Reserved
0
Channel type
4
0-6
Channel type
0x74
7
Reserved
0
Diagnostic bits
per channel
5
Number of diagnostic bit per
channel
0
Number of
channels
6
Number of similar channels
per module
8
Channel error
7-10
0-31
Reserved
0
Channel 0 error
to
Channel 31 error
11
to
42
0
–
7
Reserved
0
Time stamp
43-46
Time stamp [
μ
s] (32-bit)