Configuration and Use Manual
53
Configuring Volumetric Flow Measurement
V
o
lumetr
ic
Flo
w
Measure
ment
Histor
y
, Events, a
n
d Alar
ms
I/
O
Core Interfa
c
e
6.4
Gas Quality panel
The Gas Quality panel is shown in Figure 6-3. This panel is used to select the method that will be
used for volumetric flow measurement, and provide the required data for the selected method:
•
If the Detailed method is selected, you must configure the complete composition of the gas
mixture, using the Gas Mole Percentage fields.
•
If the Gross 1 method is selected, you must enter (not calculate):
-
Concentration of nitrogen
-
Specific gravity
-
Heating value
•
If the Gross 2 method is selected, you must enter (not calculate):
-
Concentration of nitrogen
-
Concentration of CO
2
-
Heating value
-
Specific gravity
Parameters on this panel are listed and defined in Table 6-3.
Figure 6-3
Gas Quality panel