Byte Order in IEEE
Floating Point Number
65
N/A
03, 04, 16
Applies to data received at the Model 3711.
If Byte Order is set to LSB, returns the
following:
• Register xxxx: Byte 0, byte 1
• Register xxxx + 1: Byte 2, byte 3
If Byte Order is set to MSB, returns the
following:
• Register xxxx: Byte 1, byte 0
• Register xxxx + 1: Byte 3, byte 2
66
N/A
03, 04, 16
Applies to data received at the Model 3711.
Returns:
• Register xxxx: Byte 0, byte 1
• Register xxxx + 1: Byte 2, byte 3
independent of Byte Order field.
67
N/A
03, 04, 16
Applies to data received at the Model 3711.
If Byte Order is set to LSB, returns the
following:
• Register xxxx: Byte 1, byte 0
• Register xxxx + 1: Byte 3, byte 2
If Byte Order is set to MSB, returns the
following:
• Register xxxx: Byte 0, byte 1
• Register xxxx + 1: Byte 2, byte 3
68
N/A
03, 04, 16
Applies to data received at the Model 3711.
Returns:
• Register xxxx: Byte 1, byte 0
• Register xxxx + 1: Byte 3, byte 2
independent of Byte Order field.
69
N/A
03, 04, 16
Applies to data received at the Model 3711.
If Byte Order is set to LSB, returns the
following:
• Register xxxx: Byte 2, byte 3
• Register xxxx + 1: Byte 0, byte 1
If Byte Order is set to MSB, returns the
following:
• Register xxxx: Byte 3, byte 2
• Register xxxx + 1: Byte 1, byte 0
70
N/A
03, 04, 16
Applies to data received at the Model 3711.
Returns:
• Register xxxx: Byte 2, byte 3
• Register xxxx + 1: Byte 0, byte 1
independent of Byte Order field.
71
N/A
03, 04, 16
Applies to data received at the Model 3711.
If Byte Order is set to LSB, returns the
following:
• Register xxxx: Byte 3, byte 2
• Register xxxx + 1: Byte 1, byte 0
If Byte Order is set to MSB, returns the
following:
• Register xxxx: Byte 2, byte 3
• Register xxxx + 1: Byte 0, byte 1
72
N/A
03, 04, 16
Applies to data received at the Model 3711.
Returns:
• Register xxxx: Byte 3, byte 2
• Register xxxx + 1: Byte 1, byte 0
independent of Byte Order field.
No Conversion
75 to 255
N/A
N/A
N/A
Table 12-5
Datatype conversion codes
continued
Conversion type
Conversion
code
Float scale
used
Modbus
function
Comments
Summary of Contents for Micro Motion 3711
Page 32: ...24 Micro Motion Model 3711 Gas Flow Computers ...
Page 44: ...36 Micro Motion Model 3711 Gas Flow Computers ...
Page 56: ...48 Micro Motion Model 3711 Gas Flow Computers ...
Page 68: ...60 Micro Motion Model 3711 Gas Flow Computers ...
Page 92: ...84 Micro Motion Model 3711 Gas Flow Computers ...
Page 108: ...100 Micro Motion Model 3711 Gas Flow Computers ...
Page 140: ...132 Micro Motion Model 3711 Gas Flow Computers ...
Page 196: ...188 Micro Motion Model 3711 Gas Flow Computers ...
Page 210: ...202 Micro Motion Model 3711 Gas Flow Computers ...
Page 233: ......