208
Micro Motion
®
Model 3711 Gas Flow Computers
Points and the TLP System
82
R/O
FL
4
NA
0.0
Setup Data Register 23 Value
83
R/O
UINT16
2
0 – 65535
422
Setup Reg 24 (Status Register 422)
84
R/O
UINT8
1
1 – 16
UINT16 (4)
Setup Register 24 Data Type
85
R/O
FL
4
NA
0.0
Setup Data Register 24 Value
86
R/O
UINT16
2
0 – 65535
423
Setup Reg 25 (Status Register 423)
87
R/O
UINT8
1
1 – 16
UINT16 (4)
Setup Register 25 Data Type
88
R/O
FL
4
NA
0.0
Setup Data Register 25 Value
89
R/O
UINT16
2
0 – 65535
424
Setup Reg 26 (Core Config Database
CRC)
90
R/O
UINT8
1
1 – 16
UINT16 (4)
Setup Register 26 Data Type
91
R/O
FL
4
NA
0.0
Setup Data Register 26 Value
92
R/O
UINT16
2
0 – 65535
400
Setup Reg 27 (Status Register 400)
93
R/O
UINT8
1
1 – 16
UINT16 (4)
Setup Register 27 Data Type
94
R/O
FL
4
NA
0.0
Setup Data Register 27 Value
95
R/O
UINT16
2
0 – 65535
0
Setup Reg 28 (Unused Register)
96
R/O
UINT8
1
1 – 16
UINT16 (4)
Setup Register 28 Data Type
97
R/O
FL
4
NA
0.0
Setup Data Register 28 Value
98
R/O
UINT16
2
0 – 65535
5
Setup Reg 29 (Zero Flow Cal Coil)
99
R/O
UINT8
1
1 – 16
BIN (8)
Setup Register 29 Data Type
100
R/O
FL
4
0 , 1
0.0
Setup Data Register 29 Value
101
R/O
UINT16
2
0 – 65535
136
Setup Reg 30 (Max Zero Time)
102
R/O
UINT8
1
1 – 16
UINT16 (4)
Setup Register 30 Data Type
103
R/W
FL
4
NA
0.0
Setup Data Register 30 Value
104
R/O
UINT16
2
0 – 65535
279
Setup Reg 31 (Mass Rate Meter Factor)
105
R/O
UINT8
1
1 – 16
FL (7)
Setup Register 31 Data Type
106
R/W
FL
4
NA
0.0
Setup Data Register 31 Value
107
R/O
UINT16
2
0 – 65535
189
Setup Reg 32 (Mass Damping Period)
108
R/O
UINT8
1
1 – 16
FL (7)
Setup Register 32 Data Type
109
R/W
FL
4
NA
0.0
Setup Data Register 32 Value
110
R/O
UINT16
2
0 – 65535
407
Setup Reg 33 (Flow Cal Factor)
111
R/O
UINT8
1
1 – 16
FL (7)
Setup Register 33 Data Type
112
R/W
FL
4
NA
0.0
Setup Data Register 33 Value
113
R/O
UINT16
2
0 – 65535
409
Setup Reg 34 (Flow Temp Coefficient)
114
R/O
UINT8
1
1 – 16
FL (7)
Setup Register 34 Data Type
115
R/W
FL
4
NA
0.0
Setup Data Register 34 Value
116
R/O
UINT16
2
0 – 65535
195
Setup Reg 35 (Mass Low Flow Cutoff)
117
R/O
UINT8
1
1 – 16
FL (7)
Setup Register 35 Data Type
118
R/W
FL
4
NA
0.0
Setup Data Register 35 Value
119
R/O
UINT16
2
0 – 65535
233
Setup Reg 36 (Mechanical Zero)
120
R/O
UINT8
1
1 – 16
FL (7)
Setup Register 36 Data Type
Table C-2
UDP 37 parameters
continued
Parameter
Read/
Write
Data
type
Length
Range
Default
value
Description
Summary of Contents for Micro Motion 3711
Page 32: ...24 Micro Motion Model 3711 Gas Flow Computers ...
Page 44: ...36 Micro Motion Model 3711 Gas Flow Computers ...
Page 56: ...48 Micro Motion Model 3711 Gas Flow Computers ...
Page 68: ...60 Micro Motion Model 3711 Gas Flow Computers ...
Page 92: ...84 Micro Motion Model 3711 Gas Flow Computers ...
Page 108: ...100 Micro Motion Model 3711 Gas Flow Computers ...
Page 140: ...132 Micro Motion Model 3711 Gas Flow Computers ...
Page 196: ...188 Micro Motion Model 3711 Gas Flow Computers ...
Page 210: ...202 Micro Motion Model 3711 Gas Flow Computers ...
Page 233: ......