106
E300 Installation and Commissioning Guide
Issue Number: 1
A46
V4 Speed
Reference
{
G04
}
0 to
Nominal Elevator Speed
(
A28
)
10 mm/s
RW Num
US
A47
Brake Control
Release Delay
{
D04
}
0 to 10000 ms
500 ms
RW Num
US
A48
Brake Control Apply
Delay
{
D05
}
0 to 10000 ms
500 ms
RW Num
US
A49
Start Speed Loop P
Gain
{
I01
}
0.0000 to 200.0000 s/rad
0.0300 s/rad
RW Num
US
A50
Start Speed Loop I
Gain
{
I02
}
0.00 to 655.35 s
2
/rad
0.10 s
2
/rad
RW Num
US
A51
Start Current Loop
Filter
{
I05
}
0.0 to 25.0 ms
1.0 ms
RW Num
US
A52
Run Speed Loop P
Gain
{
I06
}
0.0000 to 200.0000 s/rad
0.0300 s/rad
RW Num
US
A53
Run Speed Loop I
Gain
{
I07
}
0.00 to 655.35 s
2
/rad
0.10 s
2
/rad
RW Num
US
A54
Run Current Loop
Filter
{
I10
}
0.0 to 25.0 ms
1.0 ms
RW Num
US
A55
Start Lock Enable
{
I22
}
Off (0) or On (1)
Off (0)
RW
Bit
US
A56
Start Lock P Gain
Speed Clamp
{
I21
}
0 to 10000 mm/s
100 mm/s
RW Num
US
A57
Start Lock P Gain
{
I20
}
0.000 to 1000.000
50.000
RW Num
US
A58
Start Optimizer Time {
G48
}
0 to 10000 ms
1000 ms
RW Num
US
A59
Start Optimizer Jerk
{
G47
}
±VM_EX00_RUN_JERK_
1 mm/s
3
x 10
10 mm/s
3
x 10
RW Num
US
A60
Start Optimizer
Speed
{
G46
}
0 to 10000 mm/s
50
mm/s
10 mm/s
RW Num
US
A61
Start Optimizer
Enable
{
G45
}
Off (0) or On (1)
Off (0)
RW
Bit
US
A62
to
A80
User Menu A
Parameters Set-up
Using Menu Z
RW
Read / Write
RO
Read only
Num
Number parameter
Bit
Bit parameter
Txt
Text string
Bin
Binary parameter
FI
Filtered
ND
No default value
NC
Not copied
PT
Protected parameter
RA
Rating dependent
US
User save
PS
Power-down save
DE
Destination
IP
IP address
Mac
Mac address
Date
Date parameter
Time
Time parameter
Parameter
Range(
Ú
)
Default(
Ö
)
Type
OL
RFC-A
RFC-S
OL
RFC-A
RFC-S
Summary of Contents for E300 Series
Page 211: ......
Page 212: ...0479 0005 01 ...