104
E300 Installation and Commissioning Guide
Issue Number: 1
Table 6-2 User Menu A Open loop, RFC-A and RFC-S parameters
Parameter
Range(
Ú
)
Default(
Ö
)
Type
OL
RFC-A
RFC-S
OL
RFC-A
RFC-S
A00
Parameter {
A00
}
0 to 65535
RW Num ND NC PT
A01
User Security Status {
H02
}
User Menu A (0), All Menus (1),
Read-only User Menu A (2), Read-only (3),
Status Only (4), No Access (5)
RW
Txt
ND
PT
A02
Drive Control Mode {
B01
}
Open loop (1), RFC-A (2), RFC-S (3)
Open
loop (1)
RFC-A
(2)
RFC-S
(3)
RW
Txt
ND NC PT
A03
Parameter Cloning
{
N01
}
None (0), Read (1), Program (2),
Auto (3), Boot (4)
None (0)
RW
Txt
NC
US
A04
Total Output Current {
J22
}
+ VM_DRIVE_CURRENT_UNIPOLAR A
RO Num ND NC PT
FI
A05
Percentage Load
{
J23
}
+ VM_USER_CURRENT %
RO Num ND NC PT
FI
A06
Profile Speed
{
J39
}
0 to 10000 mm/s
RO Num ND NC PT
Actual Speed
{
J40
}
0 to 10000 mm/s
RO Num ND NC PT
A07
Output Power
{
J59
}
+ VM_POWER kW
RO Num ND NC PT
FI
A08
Output Frequency
{
J60
}
+VM_SPEED_
FREQ_REF Hz
+ 550.0 Hz
RO Num ND NC PT
FI
A09
Output Voltage
{
J61
}
+ VM_AC_VOLTAGE V
RO Num ND NC PT
FI
A10
Control Input Mode
{
H11
}
Analog Run Prmit (0), Analog 2 Dir (1),
Priority 1 Dir (2), Binary 1 Dir (3),
Priority 2 Dir (4), Binary 2 Dir (5),
Control Word (6)
Priority 1 Dir (2)
RW
Txt
US
A11
Direction Input Invert {
H12
}
Off (0) or On (1)
0ff (0)
RW
Bit
US
A12
Drive Encoder Type
{
C01
}
AB (0), FD (1), FR (2),
AB Servo (3), FD Servo (4),
FR Servo (5), SC (6),
SC Hiperface (7),
EnDat (8), SC EnDat (9),
SSI (10), SC SSI (11),
SC Servo (12), BiSS (13),
SC SC (15),
Commutation Only (16)
AB (0)
AB
Servo
(3)
RW
Txt
US
A13
Drive Encoder Auto
Configuration Select
{
C02
}
Disabled (0)
or Enabled (1)
Enabled (1)
RW
Txt
US
A14
Drive Encoder
Rotary Pulses Per
Revolution
{
C03
}
1 to 100,000 ppr
1024
ppr
4096 ppr RW Num
US
A15
Drive Encoder
Voltage Select
{
C04
}
5 V (0), 8 V (1), 15 V (2)
5V (0)
RW
Txt
US
A16
Position Feedback
Phase Angle
{
C13
}
0.0 to 359.9 °
0.0 °
RW Num ND
US
Slip Compensation
Enable
{
B10
}
Off (0) or On (1)
On (1)
RW
Bit
US
A17
Drive Encoder
Feedback Reverse
{
C12
}
Off (0) or On (1)
Off (0)
RW
Bit
US
Low Frequency
Voltage Boost
{
B12
}
0.0 to 25.0 %
3.0 %
RW Num
US
A18
Motor Rated Current {
B02
}
+ VM_RATED_CURRENT A
Maximum Heavy Duty Rating
(
J05
)
RW Num
RA
US
A19
Motor Rated Voltage {
B03
}
+ VM_AC_VOLTAGE_SET V
200 V drive: 230 V
50 Hz - 400 V drive: 400 V
60 Hz - 400 V drive: 460 V
575 V drive: 575 V
690 V drive: 690 V
RW Num
RA
US
A20
Number Of Motor
Poles
{
B05
}
Automatic (0) to 480 Poles (240)
Automatic (0)
6 Poles
(3)
RW
Txt
US
Summary of Contents for E300 Series