10
Epsilon Eb and EN Drives Reference Manual
negative changes to the
Pulse Position Input
. All edges of A and B are counted, therefore one
revolution of a 2048 line encoder will produce an 8192 count change on the
Pulse Position
Input
.
Figure 5:
Pulse/Quadrature Signals, + Command
Figure 6:
Pulse/Quadrature Signals, – Command
Pulse/Pulse Interpretation
In Pulse/Pulse interpretation, pulses received on the A channel are interpreted as positive
changes to the
Pulse Position Input
. Pulses received on the B channel are interpreted as
negative changes to the
Pulse Position Input
.
Figure 7:
Pulse/Pulse Signals, Differential Inputs
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com