Diagnostics Optimization CT MODBUS RTU Technical Data
E300 Design Guide
333
Issue Number: 1
8.9 Menu J: Monitoring
Parameter
Range(
Ú
)
Default(
Ö
)
Type
Open-Loop
RFC-A
RFC-S
Open-Loop
RFC-A
RFC-S
J01
Drive Type
0 to 255
RO
Num ND NC PT
J03
Elevator Software State
0 to 14
0 to 3
RO
Num ND NC PT
J04
Firmware Version
0 to 99999999
RO
Num ND NC PT
J05
Maximum Heavy Duty Rating
0.000 to 99999.999 A
RO
Num ND NC PT
J06
Drive Full Scale Current Kc
0.000 to 99999.999 A
RO
Num ND NC PT
J07
Drive Rated Voltage
200V (0), 400V (1), 575V (2), 690V (3)
RO
Txt
ND NC PT
J08
Drive Contol Mode Active
Open-loop (1), RFC-A (2), RFC-S (3),
Regen (4)
RO
Txt
ND NC PT US
J09
Reference Parameter Selected
0 to 10
RO
Num ND NC PT
J10
V1 Calculated Deceleration Distance
0 to 10000
RO
Num ND NC PT
J11
V2 Calculated Deceleration Distance
0 to 10000
RO
Num ND NC PT
J12
V3 Calculated Deceleration Distance
0 to 10000
RO
Num ND NC PT
J13
V4 Calculated Deceleration Distance
0 to 10000
RO
Num ND NC PT
J14
V5 Calculated Deceleration Distance
0 to 10000
RO
Num ND NC PT
J15
V6 Calculated Deceleration Distance
0 to 10000
RO
Num ND NC PT
J16
V7 Calculated Deceleration Distance
0 to 10000
RO
Num ND NC PT
J17
V8 Calculated Deceleration Distance
0 to 10000
RO
Num ND NC PT
J18
V9 Calculated Deceleration Distance
0 to 10000
RO
Num ND NC PT
J19
V10 Calculated Deceleration Distance
0 to 10000
RO
Num ND NC PT
J20
Final Current Reference
±VM_TORQUE_CURRENT %
RO
Num ND NC PT
FI
J21
Final Current Limit
±VM_TORQUE_CURRENT %
RO
Num ND NC PT
J22
Total Output Current
±VM_DRIVE_CURRENT_UNIPOLAR A
RO
Num ND NC PT
FI
J23
Percentage Load
±VM_USER_CURRENT %
RO
Num ND NC PT
FI
J24
Torque Producing Current
±VM_DRIVE_CURRENT A
RO
Num ND NC PT
FI
J25
Magnetizing Current
±VM_DRIVE_CURRENT A
RO
Num ND NC PT
FI
J26
Motor Protection Accumulator
0.0 to 100.0 %
RO
Num ND NC PT PS
J27
Final Torque Reference
±VM_TORQUE_CURRENT %
RO
Num ND NC PT
FI
J28
Final Current Filter Time Constant
0.0 to 25.0 ms
0.0 ms
RW Num
US
J29
Open-Loop: Current Controller Kp
Gain
0 to 30000
20
RW Num
US
RFC-A: Final Current Loop Kp
0 to 30000
150
RW Num
US
RFC-S: Final Current Loop Kp
0 to
30000
150 RW Num
US
J30
Final Current Loop Ki
0 to 30000
40
2000
RW Num
US
J31
Speed Error
±VM_SPEED
RO
Num ND NC PT
FI
J32
Speed Loop Output
±VM_TORQUE_CUR
RENT %
RO
Num ND NC PT
FI
J33
Final Speed Loop Kp
0.0000 to
200.0000 s/rad
0.0300 s/rad
RW Num
US
J34
Final Speed Loop Ki
0.00 to 655.35 s²/rad
0.10 s²/rad
RW Num
US
J35
Field Weakening Magnetizing Current
0 to 100 %
RO
Num ND NC PT
J36
Elevator Position
-2147483648 to
2147483647 mm
RO
Num ND NC PT
J37
Calculated Nominal Motor Speed rpm
0 to 32767 rpm
RO
Num ND NC PT
J38
Active Speed Setpoint
0 to 10000 mm/s
RO
Num ND NC PT
J39
Profile Speed
0 to 10000 mm/s
RO
Num ND NC PT
J40
Actual Speed
0 to 10000 mm/s
RO
Num ND NC PT
J41
Reference Acceleration
0 to 10000 mm/s²
RO
Num ND NC PT
J42
Deceleration Distance
0 to 32767 mm
RO
Num ND NC PT
J43
Deceleration Distance Calculated
0 to 10000 mm
RO
Num ND NC PT
J44
Deceleration Distance Measured
0 to 32767 mm
RO
Num ND NC PT
J45
Creep Distance Measured
0 to 32767 mm
RO
Num ND NC PT
J46
Speed At Floor Sensor Correction
Active
0 to 32767 mm/s
RO
Num ND NC PT
J47
Remaining Floor Sensor Correction
Distance
-32768 to 32767 mm
RO
Num ND NC PT
J48
Velocity Threshold 1 Status Output
Off (0) or On (1)
RO
Bit
ND NC PT
J49
Velocity Threshold 2 Status Output
Off (0) or On (1)
RO
Bit
ND NC PT
J50
Final Speed Reference
±VM_SPEED
RO
Num ND NC PT
FI
J51
Speed Feedback
±VM_SPEED
RO
Num ND NC PT
FI
J52
Drive Encoder Revolutions
0 to 65535
RO
Num ND NC PT PS
Summary of Contents for 03200106