Diagnostics Optimization CT MODBUS RTU Technical Data
E300 Design Guide
211
Issue Number: 1
See
Motor Thermal Time Constant 1
(
B20
).
See
Motor Thermal Time Constant 1
(
B20
).
See
Motor Thermal Time Constant 1
(
B20
).
See
Motor Thermal Time Constant 1
(
B20
).
If
Reverse Motor Phase Sequence
(
B26
) = 0 the output phase sequence is U-V-W when
Output Frequency
(
J60
) is positive and W-V-U when
Output
Frequency
(
J60
) is negative. If
Reverse Motor Phase Sequence
(
B26
) = 1 the output phase sequence is reversed so that the phase sequence in W-
V-U for positive frequencies and U-V-W for negative frequencies.
Fast Disable
(
B27
) normally shows the hardware enable state based on the state of the safe torque off system. However, drive I/O can be routed to
Fast Disable
(
B27
) to reduce the disable time. See description of the enable logic for more details.
Value
Text
0
Power down
1
Zero
2
Real time
B22
Motor Thermal Time Constant 2
Mode
Open-loop: RFC-A, RFC-S
Minimum
1.0
Maximum
3000.0
Default
89.0
Units
s
Type
16 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
1
Coding
RW
B23
Motor Thermal Time Constant 2 Scaling
Mode
Open-loop: RFC-A, RFC-S
Minimum
0
Maximum
100
Default
0
Units
%
Type
8 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
0
Coding
RW
B24
Rated Iron Losses As Percentage Of Losses
Mode
Open-loop: RFC-A, RFC-S
Minimum
0
Maximum
100
Default
0
Units
%
Type
8 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
0
Coding
RW
B26
Reverse Motor Phase Sequence
Mode
Open-loop: RFC-A, RFC-S
Minimum
0
Maximum
1
Default
0
Units
Type
1 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
0
Coding
RW
B27
Fast Disable
Mode
Open-loop: RFC-A, RFC-S
Minimum
0
Maximum
1
Default
Units
Type
1 Bit Volatile
Update Rate
2 ms read
Display Format
Standard
Decimal Places
0
Coding
RO, ND, NC, PT