Diagnostics Optimization CT MODBUS RTU Technical Data
E300 Design Guide
293
Issue Number: 1
This sets the Direct to floor deceleration distance setpoint in mm for V1 when Direct to floor operation is active,
Elevator Control Mode
(
H19
) = Direct
To Floor (1), and
Direct To Floor Sensor Mode
(
H09
) = Spd IP+User Dist (2).
This sets the Direct to floor deceleration distance setpoint in mm for V2 when Direct to floor operation is active,
Elevator Control Mode
(
H19
) = Direct
To Floor (1), and
Direct To Floor Sensor Mode
(
H09
) = Spd IP+User Dist (2).
This sets the Direct to floor deceleration distance setpoint in mm for V3 when Direct to floor operation is active,
Elevator Control Mode
(
H19
) = Direct
To Floor (1), and
Direct To Floor Sensor Mode
(
H09
) = Spd IP+User Dist (2).
This sets the Direct to floor deceleration distance setpoint in mm for V4 when Direct to floor operation is active,
Elevator Control Mode
(
H19
) = Direct
To Floor (1), and
Direct To Floor Sensor Mode
(
H09
) = Spd IP+User Dist (2).
This sets the Direct to floor deceleration distance setpoint in mm for V5 when Direct to floor operation is active,
Elevator Control Mode
(
H19
) = Direct
To Floor (1), and
Direct To Floor Sensor Mode
(
H09
) = Spd IP+User Dist (2).
G19
V1 Deceleration Distance Setpoint
Mode
RFC-A, RFC-S
Minimum
0
Maximum
10000
Default
0
Units
mm
Type
16 Bit User Save
Update Rate
Background
Display Format
Standard
Decimal Places
0
Coding
RW, Num, US
G20
V2 Deceleration Distance Setpoint
Mode
RFC-A, RFC-S
Minimum
0
Maximum
10000
Default
0
Units
mm
Type
16 Bit User Save
Update Rate
Background
Display Format
Standard
Decimal Places
0
Coding
RW, Num, US
G21
V3 Deceleration Distance Setpoint
Mode
RFC-A, RFC-S
Minimum
0
Maximum
10000
Default
0
Units
mm
Type
16 Bit User Save
Update Rate
Background
Display Format
Standard
Decimal Places
0
Coding
RW, Num, US
G22
V4 Deceleration Distance Setpoint
Mode
RFC-A, RFC-S
Minimum
0
Maximum
10000
Default
0
Units
mm
Type
16 Bit User Save
Update Rate
Background
Display Format
Standard
Decimal Places
0
Coding
RW, Num, US
G23
V5 Deceleration Distance Setpoint
Mode
RFC-A, RFC-S
Minimum
0
Maximum
10000
Default
0
Units
mm
Type
16 Bit User Save
Update Rate
Background
Display Format
Standard
Decimal Places
0
Coding
RW, Num, US