Diagnostics Optimization CT MODBUS RTU Technical Data
E300 Design Guide
281
Issue Number: 1
The scaling, offset and invert functions for analog input 3 are defined in the same way as for analog input 1. See
T5 T6 Analog Input 1 Scaling
(
F39
).
The scaling, offset and invert functions for analog input 3 are defined in the same way as for analog input 1. See
T5 T6 Analog Input 1 Scaling
(
F39
).
See
T5 T6 Analog Input 1
(
F35
).
See
T5 T6 Analog Input 1
(
F35
).
F55
T8 Analog Input 3 Destination
Mode
Open-Loop, RFC-A, RFC-S
Minimum
A00
Maximum
AB99
Default
A00
Units
Type
16 Bit User Save
Update Rate
Drive reset read
Display Format
Menu Param Alpha Numeric
Decimal Places
3
Coding
RW, DE, PT, BU
F56
T8 Analog Input 3 Offset
Mode
Open-Loop, RFC-A, RFC-S
Minimum
-100.00
Maximum
100.00
Default
0.00
Units
%
Type
16 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
2
Coding
RW
F57
T8 Analog Input 3 Minimum
Mode
Open-Loop, RFC-A, RFC-S
Minimum
-100.00
Maximum
100.00
Default
-100.00
Units
%
Type
16 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
2
Coding
RW
F58
T8 Analog Input 3 Maximum
Mode
Open-Loop, RFC-A, RFC-S
Minimum
-100.00
Maximum
100.00
Default
100.00
Units
%
Type
16 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
2
Coding
RW
F59
T8 Analog Input 3 Thermistor Type
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Maximum
9
Default
0
Units
%
Type
8 Bit User Save
Update Rate
Background read
Display Format
Standard
Decimal Places
0
Coding
RW, TE
Value
Text
0
DIN44082
1
KTY84
2
PT100 (4 W)
3
PT1000 (4 W)
4
PT2000 (4 W)
5
2.0mA (4 W)
6
PT100 (2 W)
7
PT1000 (2 W)
8
PT2000 (2 W)
9
2.0mA (2 W)