48
49
© 2021, Elon Group AB. All rights reserved.
Always ensure that the induction cooker hob is well ventilated and that the air inlet and outlet are not blocked. Ensure the induction
cooker hob is in good working condition. As shown below
NOTE:
The safe distance between the hob and any cabinet above the hob should be at
least 600 mm.
A (mm)
B (mm)
C (mm)
D (mm)
E (mm)
F (mm)
G (mm)
263
495
50 min.
50 min.
50 min.
50 min
3 mm min.
A (mm)
B (mm)
C (mm)
D
E
600
50 min.
20 min.
Air intake
Air exit 5 mm
9. Installation
9.1 Selection of installation equipment
Cut a hole in the work surface that matches the dimensions shown in the drawing.
For the purpose of installation and use, there should be a minimum of 5 cm clear space around the perimeter of the hole. Make
sure the work surface is at least 30 mm thick. Please select a heat-resistant and insulated work surface material (wood and similar
fibrous or hygroscopic materials must be avoided unless they are impregnated) to avoid electrical shock and excessive deformation
caused due to heat from the hob. As shown below:
NOTE:
The safe distance between the sides of the hob and the inner surfaces of the worktop should be at least 3 mm.
Min. 30 mm
600 mm