b.)
On the LHS undo the 8mm nut and 4mm allen screw securing the motor mount
bracket.
Fig. 3.10.2: LHS – Loosing the motor mount bracket
c.)
Slip the belt off the drive wheel and access motor from the RHS.
d.)
Unplug the motor (white plug) and remove the drive wheel from the shaft 2 x
1.5mm allen screws.
Fig. 3.10.3: RHS – Unscrewing drive wheel from the shaft
e.)
Undo the 4 x 2.5mm allen screws holding the motor and gearbox to the motor
mount.