4.1
Physical Specifications
Feature
Units
All Types
Weight
g (oz)
55 g (1.94 oz)
Dimension
mm (in)
48.5 cc (2.96 in
3
) package
(55±0.2 x 58.5±0.2 x 14.9±0.5 mm or 2.17” x 2.30” x 0.59”)
Mounting method
PCB mount
4.2
Technical Data
Feature
Units 1/100 2.5/100 5/100 10/100 15/100 20/100
Minimum supply voltage
VDC
12
Nominal supply voltage
VDC
85
Maximum supply voltage
VDC
95
Maximum continuous power
output
W
80
200
400
800
1200
1600
Efficiency at rated power (at
nominal conditions)
%
> 99
Maximum output voltage
> 95% of DC bus voltage at f = 22 kHz
Control supply
VDC
12 to 95 VDC
(up to 6 VA inc. 5 V/2 x 200 mA for encoder)
Amplitude sinusoidal/DC
continuous current
A
1.0
2.5
5
10
15
20
Sinusoidal continuous RMS
current limit (Ic)
A
0.7
1.8
3.5
7
10.6
14.1
Peak current limit
A
2 x Ic
Table 1: Technical Data
Note on current ratings:
The current ratings of the Gold Bell are given in units of DC
amperes (ratings that are used for trapezoidal commutation or DC motors). The RMS (sinusoidal
commutation) value is the DC value divided by 1.41.