62
Anom-
aly
Type of
anomaly
Description
Possible causes
Actions
Eotd
Warning
High temperature on
water drain
Possible lack of water in
the drain system.
• Check that the oven has water supply;
• Pour some fresh water on the bottom cavity
filter; pay attention, do not splash hot cavity
with cold water as it could damage the
machine.
• If the problem persists call Service.
Eprb1
Stops only
food probe
cycles
Single point core
probe failure
• Food probe misuse (for
example, wire pulled or
squeezed);
• Connector failure;
• Probe failure;
• ACU failure.
It is possible to run cycles based on time
(without food probe);
• If available, use the accessory USB food
probe;
• Call service to restore full functionality.
Epr6
Stops only
food probe
cycles
Six points core probe
failure
• Food probe misuse (for
example, wire pulled or
squeezed);
• Connector failure;
• Probe failure;
• ACU failure.
It is possible to run cycles based on time
(without food probe);
• If available, use the accessory USB food
probe;
• Call service to restore full functionality.
Ertc
Warning
Problem with internal
clock
Issue with hardware (for
example battery clock
exhausted).
It is possible that some functionality do not
work (for example HCCP).
• Call Service.
ESCH
Stops
oven
Component compart-
ment
overtemperature
• Filter is dirty;
• Too high room
temperature.
• Check room temperature considering the
oven needs fresh air to cool electronic
compartment;
• Clean the filter;
• Allow oven to cool before cooking;
• Call Service if the problem reoccurs.
EStd
Warning
Water drain NTC
failure
• Connector failure
• NTC sensor failure
• ACU failure
The oven continue to work.
• Call Service to fix the issue.
Etb
Stops
cycle/
boiler
Boiler safety thermo-
stat trips.
Overtemperature in
the boiler.
• Missing water in the
boiler;
• Limestone accumulation
in the boiler;
• Wrong insertion of the
TC probe sensor;
• The safety thermostat
bulb or the capillary are
damaged;
• Leakage of heat in the
safety thermostat body
area;
• The parameter BOT is
set too high;
• Room temperature <5°
C.
The oven is not able to produce steam with the
boiler. An alternative device will be used, but
the performance will be reduced;
• Call service to restore the boiler functionality.
EtC
Stops the
oven
Cavity safety thermo-
stat trips.
Overtemperature in
the cavity
• The cavity is dirty;
• The parameter COT is
set too high;
• The safety thermostat
bulb or the capillary are
damaged;
• The motor fan is blocked
while the heat is still On;
• The temperature TC
sensor provides erratic
measurements
• Leakage of heat in the
safety thermostat body
area.
• Room temperature <5°
C.