G.14 Periods of non-use
If the appliance is not going to be used for some time, take the
following precautions:
• close the water supply tap(s), if present;
• close the gas valves;
• disconnect the power supply or remove the plug from the
power socket, if present;
• clean the cabinet, going over all the stainless steel surfaces
vigorously with a rag moistened with paraffin oil to create a
protective film;
• periodically air the premises.
IMPORTANT
The warranty does not cover any damages caused
by ice formations in the appliance pipes.
G.15 Replacing wear and tear components
There are parts, whose damage happens because of the
ordinary use during a period, which are not covered by the
manufacturer warranty.
G.16 Repair and extraordinary maintenance
NOTE!
Repair and extraordinary maintenance have to be
carried out by specialised authorised personnel,
who can ask the manufacturer to supply a servicing
manual.
G.17 Maintenance intervals
All the components requiring maintenance are accessible from the front or the rear panel of the appliance.
The inspection and maintenance intervals depend on the actual machine operation conditions and ambient conditions (presence of
dust, damp, etc.), therefore precise time intervals cannot be given.
In any case, careful and periodical machine maintenance is advisable in order to minimise service interruptions.
To ensure constant machine efficiency, it is advisable to carry out the checks with the frequency given in the following table:
IMPORTANT
Machine maintenance, checking and overhaul operations must only be carried out by a specialised Technician or the
Customer Care Service, provided with adequate personal protection equipment (safety shoes and gloves), tools and
ancillary means;
Work on the electrical equipment must only be carried out by a specialised electrician or the Customer Care Service.
Maintenance, inspections, checks and cleaning
Frequency
Responsibility
Ordinary cleaning
• general cleaning of machine and surrounding area.
Daily
Operator
Mechanical protection devices
• check their condition and for any deformation, loosening or
removed parts.
Yearly
Service
Control
• check the mechanical part, for cracks or deformation, tighten-
ing of screws: check the readability and condition of words,
stickers and symbols and restore if necessary.
Yearly
Service
Machine structure
• tightening of main bolts (screws, fixing systems, etc.) of
machine.
Yearly
Service
Safety signs
• check the readability and condition of safety signs.
Yearly
Service
Electrical control panel
• check the electrical components installed inside the electrical
control panel. Check the wiring between the electrical panel
and machine parts.
Yearly
Service
Electrical connection cable and plug
• check the connection cable (replace if necessary) and plug.
Yearly
Service
Preventive maintenance
• remove any deposits of dirt inside the appliance.
Every 6 months
1
Service
Control
• check the conditions of the internal parts.
Every 6 months
Service
Control
• check and clean the discharge system.
Every 6 months
Service
General machine overhaul
• check all components, electrical equipment, corrosion,
pipes…
Every 10 years
2
Service
1.
In particular conditions (e. g. intensive use of the appliance, salty environment, etc.) the preventive maintenance should be more frequent.
2.
the machine is designed and built for a duration of about 10 years. After this period of time (from commissioning) the machine must undergo a general
inspection and overhaul. Some examples of checks to be carried out are given below.
• Check for any oxidised electrical components or parts; if necessary, replace them and restore the initial conditions;
• Check the structure and welded joints in particular;
• Check and replace bolts and/or screws, also checking for any loose components;