Setup
Control Unit IV Reference Manual
3-12
529-0004 Ver.3
both units) with the same parameters. See section 3.7.1 on page 3-21 for the list of
parameters that must be identical in both units.
Transmission speed
The recommended transmission speed for the Control Unit is 9600 bps (option 4). To modify
the speed:
1. At the COM) prompt, type
1
and press <Enter>. This will display the Speed options and
the current port settings.
COM)1
1-1200
2-2400
3-4800
4-9600
5-14400
6-19200
7-38400
8-57600
9-115200
?-Display menu
q-Quit and return
COM 1=9600 bps, NO parity, 8 data bits, 1 stop bit(s),
NO flow control, Protocol: Terminal, Flavor: Base
SPD)
2. Type the number (1 to 9) of the desired transmission speed and press <Enter>. The new
values are displayed confirming the modification.
COM 1=14400 bps, NO parity, 8 data bits, 1 stop bit(s),
NO flow control, Protocol: Terminal, Flavor: Base
3. Type
q
and press <Enter> to go back to the COM port menu.