6-11 Communications
Special
Commands
CMD
(hex) Name
Function
2A Key Press
Adds a value to the keyboard buffer; just like pressing a key.
Cmd:
! ADR
2A XX CSM <CR>
Reply:
A <CR>
where “XX” is the key number in hex. See “Keypad Diagnostics”
in Section 7 for a method to determine the key number for each
key on the keypad.
2B En Mot Spt
Enable “Motion ANDing” programming at operator level.
Put:
! ADR
2B P <00 or 01> CSM <CR>
Reply:
A <CR>
Get:
! ADR
2B G CSM <CR>
Reply:
A <00 or 01> CSM <CR>
where “00” = disabled, “01” = enabled.
2C En Offset
Enable “Offset” programming at operator level.
Put:
! ADR
2C P <00 or 01> CSM <CR>
Reply:
A <CR>
Get:
! ADR
2C G CSM <CR>
Reply:
A <00 or 01> CSM <CR>
where “00” = disabled, “01” = enabled.
2D En Act Pgm
“Active Program” enable at operator level.
Put:
! ADR
2D P <00 or 01> CSM <CR>
Reply:
A <CR>
Get:
! ADR
2D G CSM <CR>
Reply:
A <00 or 01> CSM <CR>
where “00” = disabled, “01” = enabled.
2E En Spd Cmp
Enable “Speed Comp” programming at operator level.
Put:
ADR
2E P XX <00 or 01> CSM <CR>
Reply:
A <CR>
Get:
! ADR
2E G XX CSM <CR>
Reply:
A <00 or 01> CSM <CR>
where “XX” is the channel number minus 1, in hex. “00” =
disabled, “01” = enabled.
2F En Timed Out
Enable “Timed Output” programming at operator level.
Put:
! ADR
2F P XX <00 or 01> CSM <CR>
Reply:
A <CR>
Get:
! ADR
2F G XX CSM <CR>
Reply:
A <00 or 01> CSM <CR>
where “XX” is the channel number minus 1, in hex. “00” =
disabled, “01” = enabled.
Serial Commands (cont’d)