3-10 Programming
Group Position Display
Menu Path
MAIN SCREEN
to CONFIG MENU
DISPLAY MENU
to GRP POS DISP
Purpose
The Group Position Display determines whether each output group can have its own
position in the machine cycle, or if all groups share one position. Because the position
of a group operating in Mode 1 or 2 changes each time the groupʼs input terminal is
energized, GRP POS DISP must be set to EACH if any groups are assigned to
Mode 1 or Mode 2.
Screen
Enable Options
Menu Path
MAIN SCREEN
to CONFIG MENU
to PGM ENABLE MENU
to ENABLE OPTIONS
Purpose
The Enable Options screen controls Operator Level access to SETUP MENU program
-
ming as indicated in Figure 21, note 1.
Screen
SETPOINTS<
ENABLE: ON
SETPOINTS or SETUP MENU screen.
Scroll through choices with UP and Down cursor keys.
OPERATOR ENABLE: ON/OFF
(Toggle with SEL key)
This screen lists the various items in the SETUP MENU, and allows you to turn Operator
access to those items on or off.
Access to the “on” items will be available only for those output channels that
have been turned ON in PER CHN ENABLE.
Programming
Press the Up Cursor and Down Cursor keys to select the function you wish to change.
Press the SEL key to turn Operator access ON or OFF.
Setup Menu Items
Access can be turned on or off for the following SETUP MENU items:
SETPOINTS, DEFAULT PROGRAM
SPEED COMP
OFFSET
MOTION DETECT
ANALOG OUTPUTS
See Also
PER CHN ENABLE
GROUP POSITION
DISPLAY: EACH<
Group Position Display Mode: EACH = Each ouput
group has its own offset value; ONE = One value
of offset is shared by all output groups.