3-11 Programming
Group Position Display (Contʼd)
The value selected in this screen determines the appearance of the main screen as
shown below:
Main Screen— • One Output Group, and GRP POS DISP Set to “One” or “Each”
• Multiple Output Groups, and GRP POS DISP set to “One”
PGM: 1 RPM: 1500
MENU< POS: 180
Machine Speed
Machine Position = Shaft Po Offset
To enter Menu Tree, press SEL when cursor is here
Active Program
Main Screen— • Multiple Output Groups and GRP POS DISP Set to “Each”
PGM: 1 RPM: 1500
MENU< GRP1: 180
Mode 1 or 2: Position = change since last reset
Mode 0, 3, 4, 5: Position = Shaft Po Group Offset
Group #: To change, put cursor here and press SEL
To enter Menu Tree, put cursor here and press SEL
Programming
Enter the GRP POS DISP function and press SEL to toggle between “ONE” and “EACH.”
• GRP POS DISP must be set to “EACH” to assign different offsets to groups through
OFFSET programming.
• If groups have been assigned different offsets through OFFSET programming, setting
GRP POS DISP to “ONE” will immediately change the individual group offsets to the
value of Group 1.
See Also
OFFSET
SHAFT POSITION
OUTPUT GROUPS
MAIN SCREEN
Increasing Direction
Menu Path
MAIN SCREEN
to CONFIG MENU
HARDWARE
to INCREASING DIR
Purpose
The Increasing Direction screen displays the direction of resolver rotation (CW or CCW
as viewed from the shaft end) that will cause the position display to increase in value.
Screen
This is normally set so the position value increases as the machine turns in its forward
direction.
Changing Direction
Press SEL to toggle the value of increasing direction. The new value will begin flashing.
Press the ENT key to confirm your selection.
INCREASING
DIR: CCW<
Direction of resolver shaft rotation (viewed from
shaft end) that will cause the postion display to
increase in value.
Summary of Contents for Plus PS-6144 Series
Page 3: ......
Page 4: ......
Page 12: ...2 2 Installation Wiring Mounting Dimensions Figure 4 Mounting Dimensions ...
Page 114: ......
Page 115: ......