3-25 Programming
Resolver Type
Menu Path
MAIN SCREEN to CONFIG MENU to HARDWARE MENU
RESOLVER TYPE
Purpose
The PS-6144 can operate with resolvers that have a transformation ratio of .454 or 1.
Standard Electro Cam resolvers have a ratio of .454. Some resolvers made by other
manufacturers have a ratio of 1.
Screen
Scale Factor
Menu Path
MAIN SCREEN to CONFIG MENU to HARDWARE MENU
SCALE FACTOR
Purpose
This function controls the number of increments into which one resolver revolution is
divided. A scale factor of 360 (0 to 359) allows the controller to operate in degrees. A
scale factor of 1024 (0 to 1023) allows positions to be programmed more accurately. In
some applications the scale factor can be set so each increment equals a unit of linear
travel.
Screen
Limits
Scale factors range from two to 1024 on standard controllers. For controllers equipped
with the “-H” option, scale factor can be as high as 4096.
Recalculations
When the scale factor is changed, all programmed setpoints are recalculated to convert
them to the new scale factor. The keypad/display will be inoperative until the calculations
are done.
RPM Update Rate
Menu Path
MAIN SCREEN to CONFIG MENU to DISPLAY
RPM UPD RATE
Purpose
The RPM Update Rate is how often the RPM display on the Main Screen is updated.
This rate can be programmed to be 1/Sec, 2/Sec, or 10/Sec.
Screen
RPM UPDATE
RATE: 1/S<
RPM Update Rate: How often RPM display on main
screen is updated; 1/Sec, 2/Sec, or 10/Sec.
Press the SEL key to toggle the selection.
RESOLVER
TYPE: ECC<
Pressing the SEL key changes resolver type to OTHER.
SCALE
FACTOR: 360<
Number of increments each revolution is broken into