3-20 Programming
Password
Menu Path
MAIN SCREEN PASSWORD
This screen provides an area to enter a password. It also shows the current programming
access level and the status of the Programming Enable terminals on the back of the
keypad, Figure 12.
Screen
Enable Levels There are three programming access levels; OPERATOR, SETUP,
and MASTER. See Figure 21 for a summary of the programming functions available
to the different levels. The codes that correspond to each level are established in the
ENABLE CODES screen.
Entering a Password
Enter a password through the numeric keypad followed by ENT. As you press the number
keys, the asterisks will be replaced by dashes. If you make a mistake, press CLR to
erase the last key you pushed.
If you enter a password that has been programmed through ENABLE CODES, the
keypad will function at the corresponding programming level. See ENABLE CODES
for a description of the various levels.
If either of the programming enable terminals on the back of the keypad is active when
a password is entered, the programming level will be whichever is greater.
Output Status (Contʼd)
Selecting Outputs
Press the SEL key to change the set of outputs displayed.
Forcing Outputs
Forcing outputs allows you to force an output on or off for diagnostic purposes. This
function is not available on earlier software models.
Note: When leaving the Output Status screen, keep in mind that any outputs that have
been forced will return to their originally programmed state.
Programming Press
to access Output 1, causing the “0” to blink. Press to turn this output on.
The “0” will change to a “1”. Select other desired outputs by pressing or . If the
output is already on, a “1” will be present instead of a “0”. So, the “1” will change to a
“0” when the output is forced.
Press
to return to output number selection. Outputs will remain forced until you
leave the Output Status screen. Press to access Outputs 9-17 on the PS-6144-17
and Outputs 9-16 or 17-25 on the PS-6144-25.
PASSWORD:--**<
LEV:NONE INP:OFF
Dashes replace asterisks as numbers are entered
PASSWORD:****<
LEV:MAS INP:OFF
Dashes change back to asterisks with ENT
Enable level shown if number matches programmed password value
PASSWORD:****<
LEV:NONE INP:OFF
Password entry area
Keypad programming terminal input status
Current programming level (hardware or software)