Entering into the first Euro phase procedure:
1) Switch the ECR to the “P” mode by pressing
.
2) Enter the code by pressing
.
3) Enter the acronym for the national currency (three characters maximum) and press
(S
UBTOTAL
) key.
4) Enter the exchange rate for Euro, maximum rate is 10000, minimum rate is 0,0001 and maximum
number of digits is 9 with max. 4 decimals (caution – in this case decimals are not recognized au-
tomatically, e.g. in the case that required value is „42,124“, it is necessary to use comma) and press
(S
UBTOTAL
).
5) Enter the currency flags according to figure 3.20 and press
(S
UBTOTAL
).
After programming, the information about transition into first phase of Euro currency is displayed. The same
information is also printed out along with values entered during the transition.
Figure 3.20. Currency flags
Digit Meaning
Valid values
1.
System of rounding
0 – up from 5,
1 – always up,
2 – always down,
3 – special quarter rounding
2.
No. of decimal places for currency displaying
0 - 3
3.
No. of decimal places for currency rounding
During the first Euro phase the actual exchange rate can be set by the following procedure:
1) Switch the ECR to the “P” mode by pressing
.
2) Press the
(D
RAWER
) key.
3) Enter the current exchange rate (maximum currency value is 10000, minimum currency value is 0,0001
and maximum number of digits is 9 with maximum 4 decimals) and press
(S
UBTOTAL
).
Before change is applied it is necessary to perform total (daily) „Z“ report.
Second Euro currency phase
In the second Euro currency phase the main currency is Euro, the secondary one is the national currency,
i.e. main and secondary replace each other (replaced are currency description code, displaying and roun-
ding flags). The customer can pay either in Euro or in the national currency. ECR grand totals will be erased
by transition into the second phase. The transition is possible only if daily, periodical and PLU report in “Z”
mode are performed. Reversal into first Euro currency phase is impossible without resetting the ECR. Call
your service technician in that case.
Entering into the second Euro currency phase procedure:
1) Switch the ECR to the “P” mode by pressing
.
2) Enter the code by pressing
.
3) Enter the actual exchange rate ( maximum rate is 10 000, minimum rate is 0,0001 and maximum num-
ber of digits is 9 with maximum 4 decimals) and press
(S
UBTOTAL
).
After programming, the information about transition into second phase of Euro currency is displayed. The
same information is also printed out along with values entered during the transition.
After transition to second phase, it is necessary to change prices of PLU articles and DPTs, as this is not
done automatically.
Summary of Contents for Euro-100T
Page 1: ...Euro 100T User manual version 1 2...
Page 2: ...m j g g v m p f g v 8 E m...
Page 7: ...INTRODUCTION...
Page 12: ......
Page 13: ...CASH REGISTER CHARACTERISTICS...
Page 23: ...PROGRAMMING MANUAL...
Page 43: ...OPERATION IN REGISTRATION MODE...
Page 63: ...REPORTS...
Page 72: ......
Page 73: ...EURO2A SOFTWARE...
Page 75: ...OPTIONAL ECR ACCESSORIES...
Page 78: ......
Page 79: ...HELPFUL ADVICE...