SCD 19102 / SMD 19102
Instruction Manual, 05/2008, A5E01588521A-002
21
Assembly
5
5.1
Mounting of unit
Ceiling suspension
The display can be mounted flush with horizontally and vertically adjacent displays.
The following must be observed when mounting (100 mm hole spacing according to VESA
standard):
Information on the fastening screws
Number
4
Thread
M4
Strength
8.8
Insertion depth
7 mm minimum / 9 mm maximum
Torque
Max. 3 Nm
0RXQWLQJSDG
6FUHZ0
'LVSOD\KRXVLQJ
PP
Figure 5-1
Insertion depth of mounting screws
See also
Safety notes (Page 11)
Installing/removing the display stand and cable for the SCD 19102 (Page 29)