Commissioning
7.4 Make settings
SCD 19102 / SMD 19102
Instruction Manual, 05/2008, A5E01588521A-002
69
To match the active resolution range to the actual video signal resolution, you must carry out
the following steps:
1.
Select Mode 4 from line 6 in the "Live mode" menu using button 2.
6HOHFW0RGHOLQH
2.
Connect complete test pattern with clearly defined frame (e.g. SMPTE image).
3.
Use the "Horizontal blank pixels" input field to shift the left edge of the SMPTE image
pixel-exact to the left internal border of the gray/blue area.
Note
Gray/blue area not visible
If no gray/blue area is visible on the left and right sides of the image, reduce the
"Horizontal resolution" until the gray/blue area becomes visible.
Setting limit reached
Since the resolution and scanning frequency can only be set within limits, the "Force"
function must be carried out when the setting limit is reached
(selected using
Mode 4 from line 6) in order to continue with the setting process. In this manner, the
slider for the setting range is again set in the center.
It may be necessary to repeat this process several times!
4.
Correct the values in the "Horizontal resolution" input field until the right internal border of
the gray/blue area is pixel-exact at the right edge of the SMPTE image.
5.
Use the "Vertical blank pixels" input field to shift the top edge of the SMPTE image pixel-
exact to the top internal border of the gray/blue area.
Note
Gray/blue area not visible
If no gray/blue area is visible on the top and bottom sides of the image, reduce the
"Vertical resolution" until the gray/blue area becomes visible.
Setting limit reached
Since the resolution and scanning frequency can only be set within limits, the "Force"
function must be carried out when the setting limit is reached
(selected using
Mode 4 from line 6) in order to continue with the setting process. In this manner, the
slider for the setting range is again set in the center.
It may be necessary to repeat this process several times!
Summary of Contents for SCD 19102
Page 2: ......
Page 8: ...Table of contents SCD 19102 SMD 19102 8 Instruction Manual 05 2008 A5E01588521A 002...
Page 14: ...Safety notes SCD 19102 SMD 19102 14 Instruction Manual 05 2008 A5E01588521A 002...
Page 76: ...Troubleshooting SCD 19102 SMD 19102 76 Instruction Manual 05 2008 A5E01588521A 002...
Page 103: ......