Commissioning
7.4 Make settings
SCD 19102 / SMD 19102
Instruction Manual, 05/2008, A5E01588521A-002
67
6HOHFW0RGHOLQH
4.
Execute "Force"
command using key 2.
Optimize scanning frequency
The correct signal frequency must now be set.
1.
Select Mode 4 from line 6 in the "Live mode" menu using button 2.
6HOHFW0RGHOLQH
2.
Connect complete SMPTE test pattern: Optimize the signal frequency in the "Total
horizontal lines" input field so that the squares of the test pattern are approximately
square.
If the squares are stretched horizontally (top and bottom edges are longer than the
sides), the value "Total horizontal lines" should be reduced.
If the squares are compressed (top and bottom edges are smaller than the sides), the
value "Total horizontal lines" should be increased.
Note
Setting limit reached
•
Since the resolution and scanning frequency can only be set within limits, the "Force"
function must be carried out when the setting limit is reached (selected using Mode 4
from line 6 in the "Live mode" menu) in order to continue with the setting process. In
this manner, the slider for the setting range is again set in the center.
It may be necessary to repeat this process several times!
•
The value "Total horizontal lines" must always be greater than the value "Horizontal
resolution". If, when setting the "Total horizontal lines", the "Horizontal resolution" is
greater, it should be reduced. A larger "Horizontal resolution" can result in the image
being split vertically.
Summary of Contents for SCD 19102
Page 2: ......
Page 8: ...Table of contents SCD 19102 SMD 19102 8 Instruction Manual 05 2008 A5E01588521A 002...
Page 14: ...Safety notes SCD 19102 SMD 19102 14 Instruction Manual 05 2008 A5E01588521A 002...
Page 76: ...Troubleshooting SCD 19102 SMD 19102 76 Instruction Manual 05 2008 A5E01588521A 002...
Page 103: ......