Commissioning
7.4 Make settings
SCD 19102 / SMD 19102
Instruction Manual, 05/2008, A5E01588521A-002
61
7.4.6
Display adjustment - Force mode
7.4.6.1
Introduction
Figure 7-3
Force Mode
NOTICE
"Force Mode" is an engineering tool
Force Mode is only used to determine exotic and unknown timings.
Using these data, an unknown timing can be implemented in the monitor.
Note
Only one timing can be saved
Force Mode cannot be used to save multiple timings.
In many cases, the unknown timing will be correctly displayed without having to use Force
Mode. This is possible because a large number of known timings are saved in the display.
Various factory-set timings are saved in the display. As soon as a video signal is connected,
an appropriate timing is searched for. During this phase, "Auto In Process" is displayed.
These timings are compatible with the standard video signals provided by current graphics
cards.
If no image or only an unclear image is displayed on the screen, the signal is outside the
standard ranges. Such signals frequently occur with older medical equipment. Such a timing
can be entered using the Force Mode functions.
Blind mode
The setting values must be known in Blind mode, and these can then be entered.
See "Blind mode " (Page 65).