Technical data
11.7 Climatic conditions
SCD 19102 / SMD 19102
Instruction Manual, 05/2008, A5E01588521A-002
81
11.7
Climatic conditions
Operation
Temperature range
5 °C ... 40 °C ambient temperature
Temperature gradient
Max. 5 °C/h, no condensation
Air pressure
1053 ... 540 hPa
Transport and storage (packed)
Temperature range
-20 °C ... +60 °C ambient temperature
Temperature gradient
Max. 5 °C/h, no condensation
Air pressure
1053 ... 540 hPa
11.8
Mechanical requirements
Operation
Vibration
To EN 60068-2-6
10 ... 58 Hz at ± 0.075 mm deflection
58 ... 500 Hz at 10 m/s²
Shock
to EN 60068-2-27 (single impact)
150 m/s², 6 ms
Under operating conditions, the device must not
be exposed to continuous or repeated shocks.
Packed unit
Vibration
To EN 60068-2-6
5 ... 9 Hz at ± 3.5 mm deflection
9 ... 500 Hz at 10 m/s²
Shock
to EN 60068-2-27 (single impact)
250 m/s², 6 ms (in storage packaging)
to EN 60068-2-29 (continuous shocks)
Summary of Contents for SCD 19102
Page 2: ......
Page 8: ...Table of contents SCD 19102 SMD 19102 8 Instruction Manual 05 2008 A5E01588521A 002...
Page 14: ...Safety notes SCD 19102 SMD 19102 14 Instruction Manual 05 2008 A5E01588521A 002...
Page 76: ...Troubleshooting SCD 19102 SMD 19102 76 Instruction Manual 05 2008 A5E01588521A 002...
Page 103: ......