11.1 Operator Level
Note
The preset values indicated apply to mode 0 (Parameter 290 = 0).
For preset values applicable to other modes see table in chapter 11.1 »Preset Values Depending on Mode«.
Parameters Designation
Unit
Max
Min
Preset
Ind.
000
c2
-
Number of stitches of start backtack forward
-
Number of stitches of start stitch condensing without
stitch regulator
-
Number of stitches of end counting chain suction
Stitches 254
0
2
001
c1
-
Number of stitches of start backtack backward
-
Number of stitches of start stitch condensing with stitch
regulator
-
Number of stitches of start counting chain suction
Stitches 254
0
4
002
c3
-
Number of stitches of end backtack backward
-
Number of stitches of end stitch condensing with stitch
regulator
-
Number of stitches of tape cutter at the start of the
seam
Stitches 254
0
2
003
c4
-
Number of stitches of end backtack forward
-
Number of stitches of end stitch condensing without
stitch regulator
-
Number of stitches of tape cutter at the seam end
Stitches 254
0
2
004
LS Light barrier compensating stitches
Stitches 254
0
7
005
LSF Number of stitches of the light barrier filter for knitted
fabrics
Stitches 254
0
1
006
LSn Number of light barrier seams
15
1
1
007
Stc Number of stitches for the seam with stitch counting
Stitches 999
0
20
008
-F A parameter from the technician level is assigned to key 9 on the
V820 control panel
1 = Softstart On/Off
2 = Ornamental backtack On/Off
3 = Start of sewing blocked with light barrier uncovered On/Off
4 = Unlocking the chain On/Off
8 = Backtack repetition On/Off
9 = Multi-backtack / standard backtack
9
1
1
009
LS Light barrier On/Off
1
0
0
010
SrM Strobel backtack in mode F-290 =56
0 = End backtack off
1 = Single end backtack on2 = Double end backtack on
3 = Double start and double end backtack on
4 = Simple start backtack and simple end tack on
4
0
0
F
013
FA Thread trimmer On/Off
1
0
0
014
Fw Thread wiper On/Off
1
0
0
015
StS Stitch counting On/Off
1
0
0
017
SAb Stop for tape cutting at the seam end On/Off
(Function only when overlock mode is active).
1
0
0
018
UoS 0 =
Sequence “overlock mode with stop”
1 =
Sequence “overlock mode without automatic stop. When the
command “run” is given, the drive runs at the pre-selected
speed. With
pedal in pos. 0
or
light barrier covered
, the
program switches to the next start of a seam without issuing
signals M1/M2.
2 =
As with setting “1”. But with
pedal in pos. 0
signals M1/M2 will
be issued, and the program switches to the next start of a
seam.
3 = As with setti
ng “1”. But with
pedal -2
signals M1/M2 will be
issued, and the program switches to the next start of a seam.
Intermediate stop and sewing foot lifting with pedal in
pedal -1
is possible.
4 = If the light barrier is covered during the end count for chain
suction, the program switches immediately to the next start of a
seam. If the end count has been completed and the light barrier
remains uncovered, the drive stops.
5 = Tape cutting at the start of the seam with stop
5
0
0
Summary of Contents for AB620A5035
Page 98: ......
Page 99: ...Instruction Manual with parameter List AB620A5035 Distribution For your notes ...
Page 100: ... AB620A5035 Parameter List 94 For your notes ...
Page 101: ... AB620A5035 Parameter List 95 For your notes ...
Page 102: ... AB620A5035 Parameter List 96 For your notes ...
Page 103: ... AB620A5035 Parameter List 97 For your notes ...