- AB620A5035
Instruction Manual
- 81 -
Parameters Designation
Unit
Max
Min
Preset
Ind.
019
-Pd 0 = Pedal in pos. -1 blocked in the seam. But with pedal in pos.
-2 sewing foot lifting is possible in the seam (function active
whenever the light barrier is On)
1 = With pedal in pos. -1 sewing foot lifting is blocked in the seam.
2 = Pedal in pos.
–2, thread trimming disabled. (Function only if
parameter 009 = 1)
3 = Pedal in pos.
–1 and –2 enabled in the seam.
4 = Pedal -1 and -2 locked in the seam (function only when
parameter 009 =1)
5 = Start seam end by with pedal -1
5
0
3
020
kLm Clamp at the seam end On/Off
1
0
0
021
ckL Run-out stitches clamp at the start of the seam
Stitches 254
0
2
022
SPO 0 = Chain suction until the end of count c2
1 = Chain suction at the seam end until pedal in pos. 0 (neutral)
2 = Chain suction until the drive is at standstill and the switch-off
start backtack (Parameter 237) has elapsed.
2
0
0
023
AFL Automatic sewing foot lifting with pedal forward at the seam end, if
light barrier or stitch counting is On.
0 = Automatic foot lifting off
1 = Automatic foot lifting On
1
0
1
024
FSP Coupled thread tension release and sewing foot lifting.
The function can be activated only with a thread trimmer that
depends on the angle.
0 = No coupling
1 = Coupled thread tension release and sewing foot at the seam
end with thread trimmer off
2 = Coupled thread tension release and sewing foot in the seam
and at the seam end with thread trimmer off
3 = Coupled thread tension release and sewing foot always
effective
3
0
0
025
tFS
Start counting (pa. 157) for thread tension release at the start of the seam
0 = Start counting at the start of the seam
1 = Start counting when the light barrier is covered
1
0
1
026
APd Characteristic of the "analog pedal"
0 = Analog function off
1 = 12-level, like previous pedal function
2 = continuously variable
3 = 24-level
4 = 60-level
5 = 48-level
6 = 48 level / standing operation (SOP; foot control 304)i
6
0
4
027
plu Area for s 1/2 of the analog pedal in percent
80
10
30
028
epd 0 = Function Off
1 = Pedal 2 release only from Pos. 1
0
1
0
030
rfw Bobbin thread monitor
0 = Off
1 = Active with stop
2 = Active without stop
3 = Active with stop and start blockage after thread trimming
4 = As 1, but with display of remaining stitches
5 = As 2, but with display of remaining stitches
6 = As 3, but with display of remaining stitches
6
0
B
031
cfw Number of stitches for bobbin thread monitor.
(The 3-digit value must be multiplied by 100).
255
0
B
037
Tu Monitoring for FF1 signal in sec
60
0
0
0
038
1FH Coupling with the 2nd thread tension release AFF1
0 = Off
1 = Coupling with FA
2 = Coupling with HP
3 = Coupling with FA and HP
3
0
0
039
1FL Coupling with foot lifting with the 2nd thread tension AFF1
0 = Off
1 = Coupling with foot lifting in the seam
2 = Coupling with foot lifting at the seam end
3 = Coupling with foot lifting in the seam and at the seam end
3
0
0
040
3FB Mode FlipFlop3
0 = Off
1 = Switched off when the foot is lifted
2 = Switched off during a reverse backtack
Summary of Contents for AB620A5035
Page 98: ......
Page 99: ...Instruction Manual with parameter List AB620A5035 Distribution For your notes ...
Page 100: ... AB620A5035 Parameter List 94 For your notes ...
Page 101: ... AB620A5035 Parameter List 95 For your notes ...
Page 102: ... AB620A5035 Parameter List 96 For your notes ...
Page 103: ... AB620A5035 Parameter List 97 For your notes ...