- AB620A5035
Instruction Manual
- 93 -
Parameters Designation
Unit
Max
Min
Preset
Ind.
294
tF2
Selection of the input function using key (B) “F2” on the
V810/V820 control panel
Functions of the key as with parameter 293, but at setting
0
key F2 is disabled.
100
0
1
297
mSO
Custom signal
0 = Function Off
1 = Signal is switched on whenever the light barrier is uncovered
(Pa.131 =1) or covered (Pa 131 =0)
2 = Signal is switched on whenever the light barrier is covered
(Pa.131 =1) or uncovered (Pa 131 =0)
3 = Signal switches on from the light barrier to the seam end.
4 = Signal M11 switches on like with setting 3. However, the signal
M5 (machine running) is switched off during output M11. When
signal M11 is issued, signal M6 (machine at standstill) is also
immediately issued.
3
0
0
298
nSo Backtack synchronization On/Off
1
0
0
299
nrS Stitch locks speed
RPM
3000
150
400
328
ob Changing function keys on the control panel
0 = All keys are locked
1 = All keys are released, key
E
+ start backtack,
key + end backtack (except mode 7)
2 = All keys are released, button
E
affects chain suction,
impacts tape cutter (only in mode 7)
3 = Button E and no function
4 = 4 = Button E, + and
– no function
5 = Button E affects soft start, impacts tape cutter
and wiper
6 = Button E affects soft start, impacts tape cutter seat
start /end
6
0
1
340
1L Lower switching threshold of input IN1
%
100
0
30
341
1L Upper switching threshold of input IN1
%
100
0
80
342
2L Lower switching threshold of input IN2
%
100
0
30
343
2h Upper switching threshold of input IN2
%
100
0
80
344
3L Lower switching threshold of input IN3
%
100
0
30
345
3h Upper switching threshold of input IN3
%
100
0
80
346
4L Lower switching threshold of input IN4
%
100
0
30
347
4h Upper switching threshold of input IN4
%
100
0
80
348
5L Lower switching threshold of input IN5
%
100
0
30
349
5h Upper switching threshold of input IN5
%
100
0
80
350
6L Lower switching threshold of input IN6
%
100
0
30
351
6h Upper switching threshold of input IN6
%
100
0
80
352
7L Lower switching threshold of input IN7
%
100
0
30
353
7h Upper switching threshold of input IN7
%
100
0
80
360
11L Lower switching threshold of input LSM
%
100
0
50
361
11h Upper switching threshold of input LSM
%
100
0
70
362
15V 5V/+15V on B18
0 =
+5V
1 = +15V
1
0
0
363
Evr Ratchet mech. Interlock on /off (F-290 = 58)
1
0
0
B
364
EWi Ratcheting bracket mech. Interlock (F290 =58)
Degrees 100
0
10
B
365
K4S Switching Strobel class (F-290 =56)
0 =
Standard Strobel machines
1 =
Class 45
2 =
VEB100-7 band cutter fixture
2
0
0
B
369
FSL Target setpoint via input PedalC with frequency (AB600A)
0 = AUS
1 = ON / PedalD =Enable
2 = ON / input function 54 = enable
2
0
0
369
FSL
370
n2 Direct input of maximum speed
RPM
F-111
F-121
Display
374
nrd Reset speed
rpm
390
70
100
B
377
tFl Time monitoring foot lifting
sec
250
0
0
B
395
Sti Stitch lock on /off (F-290 = 17)
1
0
0
B
395
Sti
396
FSL Target setpoint via input PedalC with frequency
0 = OFF
1 = ON / PedalD = Enable
2 = ON / input function 54 = Enable
2
0
0
0
Summary of Contents for AB620A5035
Page 98: ......
Page 99: ...Instruction Manual with parameter List AB620A5035 Distribution For your notes ...
Page 100: ... AB620A5035 Parameter List 94 For your notes ...
Page 101: ... AB620A5035 Parameter List 95 For your notes ...
Page 102: ... AB620A5035 Parameter List 96 For your notes ...
Page 103: ... AB620A5035 Parameter List 97 For your notes ...