7.2.2 Softstart stitches
Function
with
or
without
control panel
Parameters
Number of softstart stitches
(SSc)
100
7.3 Sewing foot lifting
Function
without
control panel
Control
Automatic in the seam
Automatic after thread trimming
Segment 7 on
Segment 8 on
Key
–
(S4)
Function
with
control panel
V810
V820
Automatic in the seam
Automatic after thread trimming
If parameter 290 = 16, with slide-in strip "7"
Left-hand arrow above key On
Right-hand arrow above key On
Left-hand arrow above key On
Key 3
Key 3
Key 6
Key 6
Key 9
Function
Parameters
Automatic sewing foot with pedal forward at the seam end if light barrier or stitch
counting is On
Coupled thread tension release and sewing foot lifting. The function can be activated
only with a thread trimmer that depends on the angle.
Switch-on delay with pedal in position
–1
Start delay after disabling the sewing foot lifting signal
Time of full power of sewing foot lifting
Duty ratio (ED) with pulsing
Delay after thread wiping until sewing foot lifting
Delay after thread trimming without thread wiper until sewing foot lifting
Upper limit ON period of sewing foot lifting 1...100
(AFL)
(FSP)
(t2)
(t3)
(t4)
(t5)
(t7)
(tFL)
(EF-)
023
024
201
202
203
204
206
211
254
Sewing foot is lifted:
in the seam
by heelback (position -1)
or automatically (using the
-
S4 key on the control, segment 7 lights up)
or automatically (using key
3
on the V810 control panel)
or automatically (using key
6
on the V820 control panel)
by pressing a key depending on the pre-selection of parameters
240...246
after thread trimming
by heelback (position -1 or -2)
or automatically (using the
-
S4 key on the control, segment 8 lights up)
or automatically (using key
3
on the V810 control panel)
or automatically (using key
6
on the V820 control panel)
by pressing a key depending on the pre-selection of parameters
240...246
automatically by light barrier when pedal forwards, according to the setting of parameter
023
automatically by stitch counting when pedal forwards, according to the setting of parameter
023
Switch-on delay after thread wiper (t7)
Switch-on delay without thread wiper (tFL)
It is possible to prevent unintentional foot lifting before thread trimming when changing from pedal position 0
(neutral) to position -2 by setting a switch-on delay (t2) using parameter
201
.
Holding power of the lifted foot:
The sewing foot is lifted by full power. Then the system switches automatically to partial power in order to
reduce the load for the control and the connected solenoid.
Set the duration of full power using parameter
203
and the partial holding power using parameter
204
.
Summary of Contents for AB620A5035
Page 98: ......
Page 99: ...Instruction Manual with parameter List AB620A5035 Distribution For your notes ...
Page 100: ... AB620A5035 Parameter List 94 For your notes ...
Page 101: ... AB620A5035 Parameter List 95 For your notes ...
Page 102: ... AB620A5035 Parameter List 96 For your notes ...
Page 103: ... AB620A5035 Parameter List 97 For your notes ...