Parameters Designation
Unit
Max
Min
Preset
Ind.
133
LSE Thread trimming operation, when completing the seam after light
barrier sensing On/Off
1
0
1
134
SSt Softstart On/Off
1
0
0
135
SrS Ornamental backtack On/Off
1
0
0
136
FAr 0 = Trimming stitch backward Off
1 = Trimming stitch backward On with single end backtack
2 = Trimming stitch or positioning stitch always backward at the seam
end
2
0
0
Parameters Designation
Unit
Max
Min
Preset
Ind.
137
hP High lift for walking foot function activated/deactivated
1
0
0
139
nIS Display of machine speed On/Off
1
0
0
140
dnE Start backtack of seam end with pedal in pos. -2
ms
2550
0
0
141
SGn Speed status for the seam with stitch counting
0 = Speed controllable by the pedal up to the set maximum speed
(Parameter 111)
1 = Fixed speed (Parameter 118) without influence by the pedal
(machine stop by pressing the pedal to the basic position)
2 = Limited speed controllable by the pedal up to the set limit
(Parameter 118)
3 = At fixed speed (Parameter 118) can be interrupted by full
heelback -2
4 = At fixed speed (Parameter 110) can be interrupted by full
heelback -2
4
0
0
142
SFn Speed status for the free seam and for the seam with light barrier
0 = Speed controllable by the pedal up to the set maximum speed
(Parameter 111)
1 = Fixed speed (Parameter 118) without influence by the pedal
(machine stop by pressing the pedal to the basic position)
2 = Limited speed controllable by the pedal up to the set limit
(Parameter 118)
3 = At fixed speed (Parameter 118) can be interrupted by full
heelback (only for seams with light barrier).
3
0
0
143
kSA Stitch counting at the start of the seam (e. g. chain suction)
0 = Speed controllable by the pedal up to the set maximum speed
(Parameter 111)
1 = Fixed speed (Parameter 112) without influence by the pedal
(machine stop by pressing the pedal to the basic position)
2 = Limited speed controllable by the pedal up to the set limit
(Parameter 112)
3 = At fixed speed (Parameter 112), can be suspended or
interrupted depending on the setting of parameter 019.
3
0
0
144
kSE Stitch counting at the seam end (e. g. chain suction)
0 = Speed controllable by the pedal up to the set maximum speed
(Parameter 111).
Fixed speed (Parameter 113) without influence by the pedal
(machine stop by pressing the pedal to the basic position).
1 = Limited speed controllable by the pedal up to the set limit
(Parameter 113)
2 = At fixed speed (Parameter 113), can be suspended or
interrupted depending on the setting of parameter 019.
3
0
0
145
Shv Speed status for the manual backtack
0 = Speed controllable by the pedal up to the set maximum speed
(Parameter 111)
1 = Fixed speed (Parameter 109) without influence by the pedal
(machine stop by pressing the pedal to the basic position)
2 = Limited speed controllable by the pedal up to the set limit
(Parameter 109)
2
0
0
150
t8 Stitch correction of the double start backtack
(prolongation of the stitch regulator ON period /not
effective with ornamental backtack)
ms
500
0
0
151
t9 Stitch correction of the double end backtack (prolongation
of the stitch regulator ON period / not effective with
ornamental backtack)
ms
500
0
0
152
thP High Lift Walking Speed Run-Out Time
ms
500
80
150
153
brt Braking power at machine standstill
50
0
15
Summary of Contents for AB620A5035
Page 98: ......
Page 99: ...Instruction Manual with parameter List AB620A5035 Distribution For your notes ...
Page 100: ... AB620A5035 Parameter List 94 For your notes ...
Page 101: ... AB620A5035 Parameter List 95 For your notes ...
Page 102: ... AB620A5035 Parameter List 96 For your notes ...
Page 103: ... AB620A5035 Parameter List 97 For your notes ...