7.13 Machine run blockage
A
TTENTION
This is not a safety function. The line voltage must still be switched off during maintenance and
repair work.
The function “machine run blockage” is enabled by connecting a switch to socket ST2, depending on the pre-
selection of parameters 240...246. When using a V810 / V820 /control panel, an acoustic signal can be switched
on and/or off by means of parameter 127.
Display after enabling machine run blockage without control panel:
Control display
Display and signal after enabling machine run blockage with control panel:
Display on the V810 control panel!
(symbol blinks and acoustic signal if parameter 127 = 1)
Display on the V820 control panel!
(symbol blinks and acoustic signal if parameter 127 = 1)
Machine run blockage in the free seam, seam with stitch counting and light barrier seam:
The seam is suspended by opening and/or closing the switch.
Stop in the basic position
Needle up is not possible
Sewing foot lifting is possible
Machine run blockage in the start backtack / start stitch condensing:
The start backtack / start stitch condensing is interrupted by opening and/or closing the switch.
Stop in the basic position
Needle up is not possible
Sewing foot lifting is possible
After disabling of the machine run blockage, the seam will be continued with the section following the start
backtack / start stitch condensing
Machine run blockage in the end backtack / end stitch condensing:
The end backtack / end stitch condensing is interrupted, and the seam is completed by opening and/or closing
the switch.
Sewing foot lifting is possible
7.14 High lift for walking foot / flip-flop 1
Function with or without control panel
Parameters
High lift for walking foot On/Off
Signal “high lift for walking foot” when key is closed/open
(hP)
(ihP)
137
263
High lift for walking foot is effective only if input function 13 or 14 has been selected using one of the parameters
240...246
and parameter
137 =1
. Select using parameter
263
whether the key is to be active when open or
when closed.
263 =0
Signal “high lift for walking foot” is issued when key is closed
263 =1
Signal “high lift for walking foot” is issued when key is opened
7.14.1 High lift walking speed
Function
with
or
without
control panel
Parameters
High lift walking speed
(n10)
117
A 2
-S t o P-
Summary of Contents for AB620A5035
Page 98: ......
Page 99: ...Instruction Manual with parameter List AB620A5035 Distribution For your notes ...
Page 100: ... AB620A5035 Parameter List 94 For your notes ...
Page 101: ... AB620A5035 Parameter List 95 For your notes ...
Page 102: ... AB620A5035 Parameter List 96 For your notes ...
Page 103: ... AB620A5035 Parameter List 97 For your notes ...