2. Service Hours Monitoring:
217 =>0
Operational mode: Number of operating hours before the next service.
Input of operating hours before the next service.
This value is compared to the operating hours counter.
The input of hours is done in steps of 10. i. e. the lowest display of 001 corresponds to 10 hours
(e. g. 055 = 550 hours).
When the set number of operating hours are reached, the message "C1" will show on the display
after each trimming operation. In addition, the speed indicator blinks on the control or on the V820
control panel during operation or after drive standstill.
Moreover, an acoustic signal is emitted when using a V810/V820 control panel if parameter
127=1
.
176
In this service routine, the total operating hours can be read out according to the procedure
example described below for parameter
177
.
177
Display of operating hours since the
last
service.
Display example of operating hours or hours since the last service and operating hours counter reset.
Display on the control:
Select parameter
177
Press the
E
key
Sr7
Press the
>>
key
h t
(hours /thousands letter symbol)
Press the
E
key
000
hours /thousands display)
Press the
E
key
h h
(hours / hundreds letter symbol)
Press the
E
key
000
(hours / hundreds display)
Press the
E
key
Min
(minutes letter symbol)
Press the
E
key
00
(minutes display)
Press the
E
key
SEc
(seconds letter symbol)
Press the
E
key
00
(seconds display)
Press the
E
key
MS
(milliseconds letter symbol)
Press the
E
key
000
(milliseconds display)
Press the
E
key
rES
See chapter "Set and Reset Operating Hours Counter"
Press the
E
key
The process will be repeated from the hours display.
Press the
P
key twice
e.g.
400
(sewing process can be started)
Display on the V810 control panel:
Select parameter
177
Press the
E
key
Sr7 [°]
Press the
>>
key
hoUr
(hours letter symbol)
Press the
E
key
000000
(hours display)
Press the
E
key
Min
(minutes letter symbol)
Press the
E
key
00
(minutes display)
Press the
E
key
SEc
(seconds letter symbol)
Press the
E
key
00
(seconds display)
Press the
E
key
MSEc
(milliseconds letter symbol)
Press the
E
key
000
(milliseconds display)
Press the
E
key
rES
F2
See chapter "Set and Reset Operating Hours Counter"
Press the
E
key
The process will be repeated from the hours display.
Press the
P
key twice
e.g.
Ab620A
(sewing process can be started)
Display on the V820 control panel:
Select parameter
177
Press the
E
key
F-177
Sr7
[°]
Press the
>>
key
hoUr
000000
(hours display)
Press the
E
key
Min
00
(minutes display)
Press the
E
key
Sec
00
(seconds display)
Press the
E
key
MSEc
000
(milliseconds display)
Press the
E
key
rES
F2
See chapter "Set and Reset Operating Hours
Counter"
Press the
P
key twice
e.g.
4000
Ab620A
(sewing process can be started)
Summary of Contents for AB620A5035
Page 98: ......
Page 99: ...Instruction Manual with parameter List AB620A5035 Distribution For your notes ...
Page 100: ... AB620A5035 Parameter List 94 For your notes ...
Page 101: ... AB620A5035 Parameter List 95 For your notes ...
Page 102: ... AB620A5035 Parameter List 96 For your notes ...
Page 103: ... AB620A5035 Parameter List 97 For your notes ...