- AB620A5035
- 39 -
Function
with
or
without
control panel
Parameters
Stop for tape cutting at the seam end On/Off
Sequence of the overlock mode (mode 7) with or without stop
Signal chain suction on seam end up to counted c2 or to pedal 0
Start counting (Parameter
157
) for thread tension release at the start of the seam
Speed during the stitch count at the seam start
Speed during the stitch count at the seam end
Stitches until thread tension release Off after light barrier covered at the start of the
seam
Enable chain suction signal and thread tension release at the seam end
Thread tension release at the seam end until pedal in pos. 0 or until the next
seam start is switched on
Braking curve in the overlock mode On/Off
Switch-off delay for chain suction at the seam end, if parameter
022 =2
Start count cancellation and seam end initiation by light barrier uncovered On/Off
(SAb)
(UoS)
(SPO)
(tFS)
(kSA)
(kSE)
(SFS)
(kSL)
(FSn)
(bdO)
(tkS)
(Abc)
017
018
022
025
143
144
157
193
199
235
237
267
There are various setting possibilities with the following parameters in the overlock mode (mode 7).
018 =0
Sequence with stop.
018 =1
Sequence withou
t automatic stop at the seam end. When the command “run” is given, the drive
runs at the pre-selected speed. The program switches to the next start of a seam without issuing
signals M1/M2, when the pedal is in pos. 0 (neutral) or the light barrier is covered.
018 =2
Sequence as with setting 1. But with pedal in pos. 0 signals M1/M2 will be issued, and the
program switches to the next start of a seam.
018 =3
Sequence as with setting 1. But with pedal -2 signals M1/M2 will be issued, and the program
switches to the next start of a seam. Intermediate stop and sewing foot lifting with pedal in pedal -
1 is possible.
018 =4
If the light barrier is covered during the end count for chain suction, the program switches
immediately to the next start of a seam. If the end count has been completed and the light barrier
remains uncovered, the drive stops immediately.
018 =5
Tape cutting at the start of the seam with stop.
022 =0
The chain suction signal at the seam end is disabled after count c2.
022 =1
The chain suction signal at the seam end remains on until pedal in pos. 0 (neutral).
022 =2
Chain suction until the drive is at standstill and the switch-off delay (Parameter
237
) has elapsed.
The switch-off delay will be disabled whenever a new seam is started.
025 =0
Start counting for thread tension release at the start of the seam.
025 =1
Start counting for thread tension release when the light barrier is covered.
193 =0
Thread tension release and chain suction after the light barrier compensating stitches.
193 =1
Chain suction from light barrier uncovered onwards and thread tension release after the light
barrier compensating stitches.
199 =0
Thread tension release On at the seam end until pedal in pos. 0 (neutral).
199 =1
Thread tension release On at the seam end or at the start of the seam.
199 =2
Thread tension release On at the seam end or at the start of the seam and after “power On“.
267 =0
Start count cancellation by light barrier uncovered impossible.
267 =1
Start count cancellation by light barrier uncovered.
Chain suction or tape cutting at the start of the seam are cancelled whenever the light barrier
senses “uncovered”, and the seam end will be initiated.
It is possible to select the speed function for stitch counting at the start of the seam and at the seam
end using the following parameters.
143 =0
Speed controllable by the pedal up to the set maximum speed (Parameter
111
).
143 =1
Fixed speed (Parameter
112
) without an affect by the pedal. Stop with pedal in pos. 0.
143 =2
Limited speed (Parameter
112
) controllable by the pedal up to the set limit.
143 =3
At fixed speed (Parameter
112
), can be cancelled or interrupted depending on the setting of parameter
019
.
144 =0
Speed controllable by the pedal up to the set maximum speed (Parameter
111
).
144 =1
Fixed speed (Parameter
113
) without an affect by the pedal. Stop with pedal in pos. 0.
144 =2
Limited speed (Parameter
113
) controllable by the pedal up to the set limit.
144 =3
At fixed speed (Parameter
113
), can be cancelled or interrupted depending on the setting of parameter
019
.
Summary of Contents for AB620A5035
Page 98: ......
Page 99: ...Instruction Manual with parameter List AB620A5035 Distribution For your notes ...
Page 100: ... AB620A5035 Parameter List 94 For your notes ...
Page 101: ... AB620A5035 Parameter List 95 For your notes ...
Page 102: ... AB620A5035 Parameter List 96 For your notes ...
Page 103: ... AB620A5035 Parameter List 97 For your notes ...