SIMS PRO
95
the plate, but the indication selection box outlines remain visible since they are still selected.
Edit
Click
Edit
on the indication ribbon to alter the percentage values of the selected indications and set
their status to accepted. The percentage values of the selected indications can be edited in one of
two ways:
1.
Set all selected indications to the
same
prove-up value.
a.
Select
Set Prove-up value
.
b.
Enter a prove-up value in the dialogue box to set all indications too.
c.
Click
OK
.
Figure 129: Edit indication by prove-up
NOTE
If indication percentages are edited to be outside of the current plate threshold range the
indications are no longer shown on the plate, but the indication selection box outlines remain
visible since they are still selected.
2.
Alter the selected indications by increasing or decreasing
each
indication by a set percentage
variation.
a.
Select
Apply percentage variation
.
b.
Enter a variation value to alter each indication percentage by.
c.
Click
OK
.
Figure 130: Edit indications by a percentage variation
NOTE
If indication percentages are edited to be outside of the current plate threshold range the
indications are no longer shown on the plate, but the indication selection box outlines remain
visible since they are still selected.
Top
Click
Top
on the indication ribbon to set the surface origin of the selected indications to become top
and set the status to accepted.
Summary of Contents for Floormap X
Page 1: ...User s Manual Floormap X MFL Array Tank Floor Inspection Solution...
Page 10: ...10 Chapter 1 Precautions and conventions...
Page 16: ...General Precautions and Conventions 16 1 5 EU Declaration of Conformity...
Page 19: ...19 Chapter 2 FloormapX System Overview...
Page 35: ...35 Chapter 3 Inspection Preparation Setup and Operation...
Page 43: ...43 Chapter 4 SIMS GO Data Acquisition Software...
Page 69: ...69 Chapter 5 SIMS PRO...