SIMS PRO
78
Layout View Navigation
Zooming and Panning
To zoom and pan around the layout you can either use a mouse or keyboard controls. Scrolling the
mouse wheel allows alters the zoom level of the layout with the zoom focused about the cursor
position. Alternatively, the zoom level can be adjusted using the keyboard
PgUp
and
PgDn
keys. Here
the zoom is focused about the center of the layout view. To pan around the layout either hold down
the mouse scroll wheel or middle mouse button or hold the
Shift
key on the keyboard together with
the mouse left button.
Switching Data Views
The inspection data displayed in the layout view can be switched to show one of the following views
using the view dropdown. Keyboard shortcut function keys can also be used to switch between the
available data views which include:
•
Top and Bottom:
F1
: displays all the indications.
•
Top:
F2
: displays top surface indications only.
•
Bottom:
F3
: displays bottom surface indications only.
•
MFLA:
F4
: displays raw data captured with the MFL array data.
•
STARS:
F5
: displays raw data captured with the STARS.
Setting Layout Units
The inspection data displayed in the layout view can be either in metric or imperial values. To set the
units:
1.
Click
File
in the ribbon.
2.
Click
Settings
in the sidebar.
3.
In the
Units
option, select either
Metric
or
Imperial
from the dropdown.
Adjusting Indication Threshold
The indication threshold control allows you to filter the indications seen on screen based on EPL. To
change the threshold:
1.
Select an indication data view: either
Top and Bottom
, or
Top
, or
Bottom
.
2.
Alter the lower or upper threshold values via the text box or the range slider bar.
NOTE
The raw data views MFLA and STARS have no threshold adjustment.
Cursor Hover Box Information
As the cursor is moved around the screen a hover box displays the measurement value at its location.
The measurement unit is determined by the layout data view.
Additional cursor information can be viewed in the cursor hover box by ticking
Show Verbose Cursor
Information
in the backstage settings. Once enabled the maximum value of the indication and its
surface origin is also displayed.
Note
The additional cursor information is only shown when indication view is set to indications.
Summary of Contents for Floormap X
Page 1: ...User s Manual Floormap X MFL Array Tank Floor Inspection Solution...
Page 10: ...10 Chapter 1 Precautions and conventions...
Page 16: ...General Precautions and Conventions 16 1 5 EU Declaration of Conformity...
Page 19: ...19 Chapter 2 FloormapX System Overview...
Page 35: ...35 Chapter 3 Inspection Preparation Setup and Operation...
Page 43: ...43 Chapter 4 SIMS GO Data Acquisition Software...
Page 69: ...69 Chapter 5 SIMS PRO...