13.5
Electrical data
Name
Type
00510X
Type
01110S
Type
03003M
Type
05010M
Type
12003M
Supply voltage [V / Hz]
100 - 240 ±10% / 50/60
Motor power [W]
30
50
IP Code
IP65
Appliance class
II
Inputs:
Level, external release, batch
max. 24 V DC / 6 mA
Pulse, standard signal (0/4-20 mA)
max. 25 mA (approx. 50 Ohm)
Minimum pulse duration (On/Off)
15 mS
Outputs:
Alarm (relay contact)
230 V, AC/DC, 3 A
Stroke signal (transistor)
max. 24 V, DC, 200 mA
External power supply
5 V, max. 100 mA
Permissible cables:
Permissible external cable diameters for connecting the inputs/outputs:
AD Ø = 5.1-5.7 mm. LIYY 4 x 0.5; LIYY 5 x 0.34; LYCY 2 x 0.34
Permissible cables: Ölflex 4 x 0.5
The IP65 is applicable only when the specified cable is being used.
13.6
Materials
n
Enclosure:
PPO (Noryl)
n
Metering head:
PP, optionally PVDF, stainless steel 1.4571
n
Diaphragm:
PTFE - EPDM composite diaphragm
n
Seals:
FKM or EPDM, either PTFE or FFPM (Kalrez)
n
Valve balls:
Ceramic, either PTFE or stainless steel 1.4401
n
Valve springs:
Hastelloy C4
n
Colour:
Blue RAL 5007
Special versions are available on request.
Technical data
189