9.3
Display view during ongoing operation (example)
Fig. 92: Operating indicator (example)
Pos. Designation
1
Pump name
Chapter 7.9.1 ‘Pump name’ on page 84
2
Maximum metering output in l/h (depending on the selected metering mode)
Chapter 9.7.1 ‘Metering mode’ on page 144
3
Metering mode (s, m, l, v)
Chapter 9.7.1 ‘Metering mode’ on page 144
4
Level display of the metering container
Chapter 9.5 ‘Changing a container - Empty signal’ on page 140
5
Maintenance display
Chapter 9.6 ‘Confirm the pump service’ on page 143
6
Display of the access code
/
and the elapsing timer for the short-term cancellation of an
access code.
7
Variable status displays (OGM, calibration, batch, external enable, access code, Bluetooth, etc.)
Chapter 9.3.1 ‘Symbols in operating mode’ on page 137
8
Current, day, date and time
Chapter 7.9.2 ‘Selecting the date/time’ on page 85
9
Test button for manual metering and to bleed the system
10
Menu button for calling up the settings
Chapter 7.6 ‘Main menu’ on page 66
11
Start button in standby position ("ON" operating mode)
12
Display of the current percentage metering capacity
13
Current metering capacity
Chapter 9.4 ‘Setting or changing the pump capacity in L’ on page 139
14
Current operating mode
Chapter 9.8.1 ‘Operating Mode’ on page 148
15
Metered chemical setting
Chapter 7.9.10 ‘Dosing chemical’ on page 98
The pump is operated via the Start button (pos. 11).
If the pump is in operation, the background of the
[Metering mode]
(pos. 3) flashes, and
the Start button changes to the Pause button .
Operation
136
Rev. 2-05.2018