68)
EBARA
CORPORATION
(8) Use the eyebolts provided on the pump for slinging the pump to load and
unload. Fasten eyebolts completely and push in until flush with the seating
surface. For sling, use a wire with a length so that the slinging angle (that is,
the angled subtended by the two wires) is within 60 degrees.
DANGER
Do not enter the zone underneath the suspended pump.
WARNING
For lifting the pump, use only qualified operator personnel.
Be sure that the wire rope and crane used for lifting the pump are in proper order
and match the weight of the pump.
To prevent unequal weight distribution, suspend the pump by ensuring that the
slinging angle remains symmetrically centered.
CAUTION
In case of sling and transportation, be sure not to remain leaning more than 10
deg against a horizontal for 5 minutes. If not, oil leakage will occur.
Fig. 9.1 Slinging the Pump
60 deg or less