CAUTION
Do not wire vacant pins.
CAUTION
Apply a 12V DC power for input signals on the pump side. Do not apply this
voltage on the equipment side.
The output signals are generated from an open collector output. Apply a voltage not
exceeding 50V DC on the equipment side.
CAUTION
Be sure to wire all signals with the correct polarity (SIG./COM.)
CAUTION
When output signals are used to energize an inductive load such as a relay, be sure
to insert a diode (100V. 1A class) in order to absorb the back electromotive force due
to surge currents.
5. Power Supply for the Options
This Power Supply is used for the option which are listed below.
(Cannot be used for other purposes.)
ADAPTER for Central Monitoring System
Interface Controller
N2 Solenoid Valve
WARNING
Power Supply for the options is kept applying voltage when Earth Leakage
Breaker (ELB) turns on during the pump is supplied the power.
CAUTION
Do not use the power supply for other purposes.