Eaton
®
Power Xpert
®
9395P-600 (300V-600V) Installation and Operation Manual 164000710—Rev 07
193
are attached, and transmits that data every 15 minutes (or 96 times per day), enabling real-time monitoring and
advanced virtual preventive maintenance.
88..33
P
Poow
weerr M
Maannaaggeem
meenntt S
Sooffttw
waarree
Eaton’s software solutions, based on Web2.0 technology, include two applications: Intelligent Power
Manager
®
for UPS management and monitoring, and Intelligent Power Protector
®
, which allows graceful
shutdown of operating systems.
Eaton’s Intelligent Power Software gives you all the tools you need to monitor and manage power devices on
your network, even in a virtualized environment. This innovative software solution combines the most critical
applications in ensuring system uptime and data integrity: not only power monitoring and management, but
also graceful shutdown during an extended power outage.
Because it can manage redundant power systems, it is an ideal solution for the most critical IT environments
with stringent requirements for power availability and reliability. Yet it is easy to use – the software scales
flexibly from a simple single-computer, single-UPS configuration, to the most sophisticated high availability
environments.
The software’s mass configuration capabilities make installation and maintenance easy, which minimizes the
effort required and benefits the bottom line. Eaton’s cost effective Intelligent Power Software manages up to
ten devices at no charge, with licences for up to 100 devices – or even an unlimited number – also available.
Contact your Eaton Sales representative for additional information.
88..44
B
Buuiillddiinngg A
Allaarrm
m M
Moonniittoorriinngg
This standard feature lets you connect the UPS to your building alarms, such as smoke detectors or over-
temperature alarms. The customer interface terminals for external connections are located inside the UPS. You
should use twisted-pair wires for each alarm input and common.
The building alarms can be programmed to display the alarm functional name.
88..55
G
Geenneerraall P
Puurrppoossee R
Reellaayy C
Coonnttaacctt
One general purpose relay contact is provided as a standard feature on the UPS. The alarm contact is located
inside the UPS on the customer interface terminal board.
You can use a normally-closed or normally-open contact. If the state of the contact changes from the state you
specify as normal, a signal is issued. You can connect this contact to equipment at your facility (such as a light
or an alarm bell) to let you know when an alarm is active on the UPS. This feature is useful if the UPS is located
in a remote area where the UPS horn may not be heard immediately.
Contacts should not be operated in excess of 30 Vac @ 5A maximum.
ATTENTION!
Ne pas faire fonctionner les contacts à plus de 30 VCA à 5 A maximum.
88..66
R
Reem
moottee M
Moonniittoorr P
Paanneell IIII
As an option, an RMP II can be installed to monitor the operation of the UPS system from virtually any location
within the facility, up to 150m (500 ft) from the UPS. The RMP II contains backlit status indicators and a local
horn. The RMP II can be flush–mounted or surface–mounted on a desktop, or secured to a wall.
shows an RMP II.