Read/write function blocks
73
09/10 MN05013007Z-EN
Analog value comparator A1 – A8: write actual values
(function, comparison values)
Remember this feature when uploading, downloading or
comparing “easy” circuit diagrams with easySoft. When
downloading from the PC the latest version of the “*.eas” is
overwritten. The comparison shows that the circuit diagrams
are not identical.
Byte
Meaning
Value (hex), sent by
Bit
M
S
Master
Slave
7 6 5 4 3 2 1 0
Attribute ID: Write
A1
22
–
0 0 1 0 0 0 1 0
A2
23
–
0 0 1 0 0 0 1 1
A3
24
–
0 0 1 0 0 1 0 0
A4
25
–
0 0 1 0 0 1 0 1
A5
26
–
0 0 1 0 0 1 1 0
A6
27
–
0 0 1 0 0 1 1 1
A7
28
–
0 0 1 0 1 0 0 0
A8
29
–
0 0 1 0 1 0 0 1
0
Response
Write successful
–
C1
1 1 0 0 0 0 0 1
Command
rejected
–
C0
1 1 0 0 0 0 0 0
0
1
Control byte:
00
1
2
Comparison value
for comparison with
constant
00
M
= master
S
= Slave
h
Keep to the value range: The comparison values as well as
the function are part of an “*.eas file”. If these values are
changed, the original “*.eas file” no longer matches the
file in the EASY6….