Control commands for easy600
86
09/10 MN05013007Z-EN
Timing relays T1 – T8: write parameters
(timing range, reference value, switching function)
Byte
Meaning
Value (hex), sent by
Bit
M
S
Master
Slave
7 6 5 4 3 2 1 0
Attribute ID: Write
T1
01
–
0 0 0 0 0 0 0 1
T2
02
–
0 0 0 0 0 0 1 0
T3
03
–
0 0 0 0 0 0 1 1
T4
04
–
0 0 0 0 0 1 0 0
T5
05
–
0 0 0 0 0 1 0 1
T6
06
–
0 0 0 0 0 1 1 0
T7
07
–
0 0 0 0 0 1 1 1
T8
08
–
0 0 0 0 1 0 0 0
0
Response
Write successful
–
C1
1 1 0 0 0 0 0 1
Command
rejected
–
C0
1 1 0 0 0 0 0 0
0
1
Control byte:
invalid
1
2
Low reference value
00
2
3
High reference
value
3 – 5
4 – 6
00
00
M
= master
S
= Slave