Control commands for easy700
128
09/10 MN05013007Z-EN
Table 57:
Operand overview
Index
(hex)
Operand
Read
Write
00
Parameters
x
01
Control byte
x
02
Comparison value 1
I1
2)
x
c
1)
03
Comparison value 2
I2
2)
x
c
1)
04
Gain factor for I1
(I1 = F1
x
I1)
F1
2)
x
c
1)
05
Gain factor for I2
(I2 = F2
x
I2)
F2
2)
x
c
1)
06
Offset for value I1 (I1 = OS
+ actual value at I1)
OS
2)
x
c
1)
07
Switching hysteresis for
value I2
HY
2)
x
c
1)
1) The value can only be written if it is assigned to a constant in the
program.
2) A 16-bit value is transferred in data bytes Data 1 – Data 2.
Be aware that the low byte is kept in Data 1 (byte 5) and the high byte
in Data 2 (byte 8).
Example: 5327
dec
= 14CF
hex
l
Data 1 = 0xCF, Data 2 = 0x14