Machine description
4812164901_A.pdf
2022-11-14
Safety instructions for connecting cables
In order to prevent external short circuit,
disconnect power terminals and signal interface
terminal before dismounting the battery pack
from the machine.
In order to prevent external short circuit,
disconnect power terminals and signal interface
terminal before dismounting the battery pack
from the machine.
In order to prevent external short circuit, make
sure that external cabling between battery
system and machine frame is not cut or
damaged during dismounting.
In order to prevent external short circuit, make
sure that external cabling between battery
system and machine frame is not cut or
damaged during dismounting.
Safety instructions for handling the damaged
battery system
Do not expose the battery system to excessive
heat or external fire to prevent damaging the
battery packs thermally.
Do not expose the battery system to excessive
heat or external fire to prevent damaging the
battery packs thermally.
Obey the temperature ranges when storing and
operating the battery system to prevent
damaging the battery packs thermally.
Obey the temperature ranges when storing and
operating the battery system to prevent
damaging the battery packs thermally.
Handle a damaged battery pack with care. Wear
personal protective equipment (safety goggles,
gloves, and apron) when handling a damaged
battery system.
Handle a damaged battery pack with care. Wear
personal protective equipment (safety goggles,
gloves, and apron) when handling a damaged
battery system.
Mechanically damaged batteries or batteries
exposed to fire or heat can have chemical
reaction causing possible thermal runaway.
Damaged batteries or battery system covers can
be extremely hot even if there are no visible
flames or smoke.
Mechanically damaged batteries or batteries
exposed to fire or heat can have chemical
reaction causing possible thermal runaway.
Damaged batteries or battery system covers can
be extremely hot even if there are no visible
flames or smoke.
Mechanically damaged Li-ion batteries may leak
electrolyte. Place the damaged battery in a
container of sand or another chemically inert
material when storing the battery before proper
disposal.
Mechanically damaged Li-ion batteries may leak
electrolyte. Place the damaged battery in a
container of sand or another chemically inert
material when storing the battery before proper
disposal.
Transportation of the damaged battery system
shall be done according to UN38.3. See
chapter 10 Transportation.
Transportation of the damaged battery system
shall be done according to UN38.3. See
chapter 10 Transportation.
45
Summary of Contents for CC1000 e
Page 2: ......
Page 10: ...e 4812164901_A pdf 2022 11 14...
Page 28: ...Technical specifications 4812164901_A pdf 2022 11 14 18...
Page 66: ...Machine description 4812164901_A pdf 2022 11 14 56...
Page 82: ...Operation 4812164901_A pdf 2022 11 14 72...
Page 92: ...Operating instructions Summary 4812164901_A pdf 2022 11 14 82...
Page 94: ...Operating instructions Summary 4812164901_A pdf 2022 11 14 84...
Page 96: ...Preventive maintenance 4812164901_A pdf 2022 11 14 86...
Page 108: ...Maintenance 50h 4812164901_A pdf 2022 11 14 98...
Page 112: ...Maintenance measures every other month 4812164901_A pdf 2022 11 14 102...
Page 118: ...Maintenance measures 500 h 4812164901_A pdf 2022 11 14 108...
Page 129: ......
Page 130: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden www dynapac com...