5
2. Technical parameters
power supply: 12…24V AC/DC ±10%;
power consumption 50mA;
operational temperature: -20°C do +55°C;
memory capacity: 9 999 remotes, each with individual number;
event memory capacity: 50 000 positions;
manual control output to release receiver channels: programmed type (NO/NC), time of output breach (0...9s),
possibility to assign any combination of outputs;
relay outputs on the base board of the receiver (type / quantity / maximum load): NO or NC / 2 / 1A 24V AC or DC;
optional 2 additional outputs – REL-2 or REL-2-PWR modules;
optional Wi-Fi WL2 card module;
optional SHR-F433 radio module enabling cooperation with DTM433MHz series remotes;
outputs operational modes: monostable, bistable or pulse mode;
output support time regulation in monostable mode: 0,1s to 6553,5s with 0,1s resolution;
radio module: modern, digital, super heterodye with intelligent adaptation to external radio conditions ensuring
reliability, repeatability and optional sensitivity;
radio transmission security: 104-bit IRS;
modulation type / frequency: FSK/868MHz;
aerial output impedance: 50Ω
aerial: wire, clamps to connect external aerial, rod aerial on the casing optional;
splash-proof (IP-54) plastic surface casing;
openings in the receiver board are suitable for installation in buffer power supply unit casings;
receiver memory: on the support;
user interface: buttons and LED display;
possibility to protect the access to the receiver menu with PIN code;
real time clock with battery support for events registration;
fast assigning of the remote button to the channel of the receiver;
possibility to assign any remote button to any receiver channel;
remote edition without its physical presence on the basis of its reference number;
possibility to delete all memory;
possibility to delete single remote;
possibility to assign the remote without the access to receiver buttons: function of remote assigning of the
remote control (in the radio range of the receiver); possible blockade of Remote assigning function
function of transmitting the number of assigned remotes;
security against accidental start with the use of the remote: double click of the remote button function
function of copying the setting for the programmed remote: from Any other remote configured earlier.
Summary of Contents for cloud FLEX
Page 1: ...v 1 3 ...
Page 25: ...25 Fig 23 Assigning receiver channels to the manual control output Sr CA function ...
Page 26: ...26 Fig 24 Programming of manual control output type Sr In function OUTPUT TYPE NO NC ...
Page 27: ...27 Fig 25 Programming of breach time of manual control output Sr ti function ...
Page 40: ...40 ...