16
5.2. PC option –receiver channels programming
5.2.1. Bistable and monostable (connection time) programming mode
The time in monostable mode possible to set is between 0,1 sec to 6553,5 sec (about 110 min). The channel
connection time can be changed with the resolution of 0,1 sec.
Setting the time 0sec causes the channel to operate in the bistable mode and setting the time bigger than zero
switches on operation in monostable mode.
According to factory settings every channel has 0 000.5 – which is equal to 0,5 sec and operation in monostable mode.
To change the channel connection time it is necessary to (Fig. 15):
in main menu with NEXT button choose PC option and press OK/ESC button of the receiver; the display shows
'PC.C1';
with NEXT button choose needed channel and press OK./ESC button of the receiver;
short pressing of NEXT button causes the change of value, long – change of digit edited; accept the time set by
pressing OK/ESC button;
At any time it is possible to withdraw from the edition by pressing and holding OK./ESC button of the receiver.
.
If the channel given is set in the pulse mode '----' are shown. Setting the time causes automatic switching off of pulse
mode.
Fig. 15
Programming of monostable/bistable modes of receiver channels, PC.C1...4. function.